-
J Comput Assist Tomogr · Mar 2014
Usefulness of adding SPECT/CT to 99mTc-hexamethylpropylene amine oxime (HMPAO)-labeled leukocyte imaging for diagnosing prosthetic joint infections.
- Hye Ok Kim, Sae Jung Na, Seung Jun Oh, Bong Sung Jung, Soo-Ho Lee, Jae Suk Chang, Seong-Il Bin, and Jin-Sook Ryu.
- From the *Department of Nuclear Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea; †Department of Radiology, Uijeongbu St. Mary's Hospital, The Catholic University of Korea, Seoul, Korea; ‡Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
- J Comput Assist Tomogr. 2014 Mar 1; 38 (2): 313-9.
ObjectiveThis study evaluated the usefulness of adding single-photon emission computed tomography (SPECT)/computed tomography (CT) (SPECT/CT) to technetium Tc 99m (Tc) hexamethylpropylene amine oxime (HMPAO)-labeled leukocyte imaging for diagnosing infections in hip or knee joint prostheses.MethodsThe Tc-HMPAO-labeled leukocyte scans of 164 patients (71 with hip prostheses and 93 with knee prostheses) with clinically suspected prosthetic infections were reviewed retrospectively. Planar images were taken 4 to 6 and 21 to 26 hours after injecting the labeled leukocytes and SPECT/CT images were obtained 4 to 6 hours after the injection. The final diagnosis of infection was based on pathologic findings (n = 70), bacteriological data (n = 61), or clinical follow-up (n = 33).ResultsOf the 164 patients, 89 patients had a diagnosis of prosthetic joint infections. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy of the planar images alone were 82.0%, 88.0%, 89.0%, 80.5%, and 84.8%, respectively. When the planar images were combined with SPECT, the sensitivity, specificity, PPV, NPV, and diagnostic accuracy were 91.0%, 88.0%, 90.0%, 89.2%, and 89.6%, respectively. When the planar images were combined with SPECT/CT, these values increased further to 93.3%, 93.3%, 94.3%, 92.1%, and 93.3%, respectively. Adding CT to SPECT resulted in a greater increase in sensitivity and specificity for hip prosthesis infections than for knee prosthesis infections. SPECT/CT mainly contributed by precisely localizing the anatomical site of the active inflammatory lesion and by delineating the extent of the lesion after diagnosis with SPECT.ConclusionsSingle-photon emission computed tomography/CT combined with Tc-HMPAO-labeled leukocyte imaging was useful for diagnosing prosthesis infections, particularly in hip prosthesis infections, as it improved diagnostic accuracy and provided anatomical localization data.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.