• Clinical radiology · Mar 2015

    Breast DWI at 3 T: influence of the fat-suppression technique on image quality and diagnostic performance.

    • Luisa Nogueira, Sofia Brandão, Rita G Nunes, Hugo Alexandre Ferreira, Joana Loureiro, and Isabel Ramos.
    • Department of Radiology, School of Health Technology of Porto/Polytechnic Institute of Porto (ESTSP/IPP), Rua Valente Perfeito, 4400-330, Vila Nova de Gaia, Portugal; Department of Radiology, Hospital de São João/Faculty of Medicine of Porto University (FMUP), Alameda Prof. Hernâni Monteiro, 4200-319 Porto, Portugal. Electronic address: mlpnogueira@med.up.pt.
    • Clin Radiol. 2015 Mar 1; 70 (3): 286-94.

    AimTo evaluate two fat-suppression techniques: short tau inversion recovery (STIR) and spectral adiabatic inversion recovery (SPAIR) regarding image quality and diagnostic performance in diffusion-weighted imaging (DWI) of breast lesions at 3 T.Materials And MethodsNinety-two women (mean age 48 ± 12.1 years; range 21-78 years) underwent breast MRI. Two DWI pulse sequences, with b-values (50 and 1000 s/mm(2)) were performed with STIR and SPAIR. The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), suppression homogeneity, and apparent diffusion coefficient (ADC) values were quantitatively assessed for each technique. Values were compared between techniques and lesion type. Receiver operating characteristics (ROC) analysis was used to evaluate lesion discrimination.ResultsOne hundred and fourteen lesions were analysed (40 benign and 74 malignant). SNR and CNR were significantly higher for DWI-SPAIR; fat-suppression uniformity was better for DWI-STIR (p < 1 × 10(-4)). ADC values for benign and malignant lesions and normal tissue were 1.92 × 10(-3), 1.18 × 10(-3), 1.86 × 10(-3) s/mm(2) for DWI-STIR and 1.80 × 10(-3), 1.11 × 10(-3), 1.79 × 10(-3) s/mm(2) for SPAIR, respectively. Comparison between fat-suppression techniques showed significant differences in mean ADC values for benign (p = 0.013) and malignant lesions (p = 0.001). DWI-STIR and -SPAIR ADC cut-offs were 1.42 × 10(-3) and 1.46 × 10(-3) s/mm(2), respectively. Diagnostic performance for DWI-STIR versus SPAIR was: accuracy (81.6 versus 83.3%), area under curve (87.7 versus 89.2%), sensitivity (79.7 versus 85.1%), and specificity (85 versus 80%). Positive predictive value was similar.ConclusionThe fat-saturation technique used in the present study may influence image quality and ADC quantification. Nevertheless, STIR and SPAIR techniques showed similar diagnostic performances, and therefore, both are suitable for use in clinical practice.Copyright © 2014 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…