• Ann. Thorac. Surg. · Nov 1995

    Multicenter Study Comparative Study Clinical Trial Controlled Clinical Trial

    Comparing two strategies of cardiopulmonary bypass cooling on jugular venous oxygen saturation in neonates and infants.

    • F H Kern, R M Ungerleider, S R Schulman, J N Meliones, R M Schell, B Baldwin, P R Hickey, M F Newman, R A Jonas, and W J Greeley.
    • Department of Anesthesiology, Duke University Medical Center, Durham, North Carolina 27710, USA.
    • Ann. Thorac. Surg. 1995 Nov 1; 60 (5): 1198-202.

    BackgroundCerebral protection during deep hypothermic circulatory arrest is predicted on efficient and complete cerebral cooling. Institutions approach cooling quite differently. We compared two different cooling strategies in terms of measured jugular venous bulb saturations in 39 infants undergoing deep hypothermic cardiopulmonary bypass to evaluate the effect of institutional cooling practices on jugular venous bulb saturation, an indirect measure of cerebral cooling efficiency.MethodsThe patients were grouped based on the method of core cooling. In group A (n = 17), core cooling was achieved rapidly by setting the water bath temperature of the heat exchanger at 4 degrees to 5 degrees C, and the patient was cooled until rectal temperature and nasopharyngeal temperature were 15 degrees C or lower. In group B (n = 22), the heat exchanger was initially set at 18 degrees C and slowly lowered to 12 degrees C. Hypothermic temperatures of 12 degrees C were maintained until the nasopharyngeal temperature was 18 degrees C or less and the rectal temperature was 20 degrees C or lower. Once cooling was complete, blood samples were analyzed by cooximetry for determination of arterial oxygen saturation and jugular venous bulb saturation.ResultsIn group A, the measured jugular venous bulb saturation was 98.0% +/- 0.9% and the oxygen saturation to jugular venous bulb saturation difference was 0.3% +/- 0.5%, measured at the time that institutional cooling objectives were achieved (total cooling time, 15.0 +/- 0.45 minutes). In group B, jugular venous bulb saturation was 86.2% +/- 12% and the oxygen saturation to jugular venous bulb saturation difference was 10.8% +/- 12.2%, measured at the time that institutional cooling objectives were achieved (total cooling time, 17.5 +/- 1.1 minutes (p < 0.01).ConclusionsDifferences in cardiopulmonary bypass cooling techniques may alter the rate at which jugular bulb saturations rise. We believe this represents an indirect measure of the efficiency of brain cooling and therefore of cerebral protection.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.