• Chest · Oct 2010

    Comparative Study

    In vitro evaluation of endotracheal tubes with intrinsic suction.

    • Karla I Mujica-Lopez, Melissa A Pearce, Kyle A Narron, Jorge Perez, and Bruce K Rubin.
    • Department of Pediatrics, Virginia Commonwealth University, Richmond, VA, USA.
    • Chest. 2010 Oct 1; 138 (4): 863-9.

    BackgroundEndotracheal tube (ETT) intubation impairs mucus clearance, which can lead to respiratory compromise. We compared three ETTs that have intrinsic capacity to aspirate secretions pooling above the cuff.MethodsWe evaluated the ability of three ETTs with suction, Hi-Lo Evac, Teleflex ISIS, and Portex Blue Line SACETT, to aspirate saliva and mucus simulants at continuous or intermittent vacuum pressures. We also evaluated the potential for a flexible tracheal membrane to obstruct the ETT suction port with applied vacuum. We measured the dimensions of the suction tubing at critical points to calculate differences in flow.ResultsIn a rigid tracheal model, the ISIS aspirated saliva simulant more quickly with continuous low pressure suction than Evac (P = .0006) and SACETT (P < .0001) as well as with intermittent high pressure suction (P < .0001). For mucus simulant, the ISIS aspirated stimulant better than the other ETTs at high intermittent suction (P < .0001); the Evac was more effective than the SACETT (P = .0019). For low and continuous suction, suction ports in all ETTs occluded with mucus, except for ISIS, at the highest continuous suction tested. In a trachea model with a flexible posterior membrane, this membrane either partially or completely occluded the suction port of all tubes at high continuous or intermittent suction. The ISIS was more prone to obstruction by the flexible membrane than the Evac. We found large differences in suction tubing cross-sectional area between the ISIS and the other tubes, and flow calculations using the Hagen-Poiseuille equation can explain the observed differences in volumes aspirated and tendency toward lumen obstruction.ConclusionsThe ISIS transmits suction pressure to the tube orifice more powerfully than the Evac and SACETT. This feature makes the ISIS less prone to obstruction by mucus but more likely to obstruct by tissue suction.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…