• Circ Heart Fail · Nov 2019

    Multicenter Study Comparative Study

    Clinical Practice Patterns in Temporary Mechanical Circulatory Support for Shock in the Critical Care Cardiology Trials Network (CCCTN) Registry.

    • David D Berg, Christopher F Barnett, Benjamin B Kenigsberg, Alexander Papolos, Carlos L Alviar, Vivian M Baird-Zars, Gregory W Barsness, Erin A Bohula, Joseph Brennan, James A Burke, Anthony P Carnicelli, Sunit-Preet Chaudhry, Paul C Cremer, Lori B Daniels, Andrew P DeFilippis, Daniel A Gerber, Christopher B Granger, Steven Hollenberg, James M Horowitz, James D Gladden, Jason N Katz, Ellen C Keeley, Norma Keller, Michael C Kontos, Patrick R Lawler, Venu Menon, Thomas S Metkus, P Elliott Miller, Jose Nativi-Nicolau, L Kristin Newby, Jeong-Gun Park, Nicholas Phreaner, Robert O Roswell, Steven P Schulman, Shashank S Sinha, R Jeffrey Snell, Michael A Solomon, Jeffrey J Teuteberg, Wayne Tymchak, Sean van Diepen, and David A Morrow.
    • Levine Cardiac Intensive Care Unit, TIMI Study Group, Cardiovascular Division, Department of Medicine, Brigham and Women's Hospital and Harvard Medical School, Boston, MA (D.D.B., V.M.B.-Z., E.A.B., J.-G.P., D.A.M.).
    • Circ Heart Fail. 2019 Nov 1; 12 (11): e006635.

    BackgroundTemporary mechanical circulatory support (MCS) devices provide hemodynamic assistance for shock refractory to pharmacological treatment. Most registries have focused on single devices or specific etiologies of shock, limiting data regarding overall practice patterns with temporary MCS in cardiac intensive care units.MethodsThe CCCTN (Critical Care Cardiology Trials Network) is a multicenter network of tertiary CICUs in North America. Between September 2017 and September 2018, each center (n=16) contributed a 2-month snapshot of consecutive medical CICU admissions.ResultsOf the 270 admissions using temporary MCS, 33% had acute myocardial infarction-related cardiogenic shock (CS), 31% had CS not related to acute myocardial infarction, 11% had mixed shock, and 22% had an indication other than shock. Among all 585 admissions with CS or mixed shock, 34% used temporary MCS during the CICU stay with substantial variation between centers (range: 17%-50%). The most common temporary MCS devices were intraaortic balloon pumps (72%), Impella (17%), and veno-arterial extracorporeal membrane oxygenation (11%), although intraaortic balloon pump use also varied between centers (range: 40%-100%). Patients managed with intraaortic balloon pump versus other forms of MCS (advanced MCS) had lower Sequential Organ Failure Assessment scores and less severe metabolic derangements. Illness severity was similar at high- versus low-MCS utilizing centers and at centers with more advanced MCS use.ConclusionsThere is wide variation in the use of temporary MCS among patients with shock in tertiary CICUs. While hospital-level variation in temporary MCS device selection is not explained by differences in illness severity, patient-level variation appears to be related, at least in part, to illness severity.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…