• Chest · Sep 1996

    Reproducibility of cardiopulmonary exercise parameters in patients with valvular heart disease.

    • G Lehmann and K Kölling.
    • Department of Cardiology, Munich, Federal Republic of Germany.
    • Chest. 1996 Sep 1; 110 (3): 685-92.

    Study ObjectivesTo determine the degree of reproducibility of exercise parameters in patients with chronic heart failure. Parameters such as treadmill walking time (TWT), oxygen uptake (Vo2), heart rate, oxygen pulse, minute ventilation (VE) ventilatory equivalents for oxygen uptake (VE/Vo2) and carbon dioxide output (Vco2), and respiratory quotient at both anaerobic threshold (AT) and peak exercise (PE) each were assessed.DesignUsing the Naughton-Weber protocol, two repeated cardiopulmonary treadmill exercise tests were performed after detailed instructions prior to the first test and on strict adherence to standardized investigational conditions, viz, at the same time of day and at the same ambient temperature, receiving constant medication, and while in a 12-h fasting state.PatientsThe studies were carried out in 17 patients with chronic heart failure due to valvular heart disease considered candidates for intervention because of symptoms. According to Weber's classification of functional capacity, 10 patients were in class A (Vo2 max > 20 mL O2/min/kg), 5 patients were in class B (16 to 20 mL O2/min/kg), and the remaining 2 were in class C (10 to 16 mL O2/min/kg).MeasurementsParameters assessed were TWT, Vo2, heart rate, oxygen pulse, VE and ventilatory equivalents for oxygen (VE/Vo2) and carbon dioxide (VE/Vco2) both at AT and at PE. To reflect reproducibility, correlation coefficients (r) were calculated.ResultsAn excellent reproducibility was found for TWT (r = 0.963, p < 0.0001), Vo2 at AT in percent of predicted Vo2max (r = 0.984, p < 0.0001), Vo2 at PE (r = 0.996, p < 0.0001), heart rate at AT (r = 0.943, p < 0.0001) and at PE (r = 0.928, p < 0.0001), oxygen pulse at AT (r = 0.980, p < 0.001) and at PE (r = 0.991, p < 0.0001), VE at AT (r = 0.949, p < 0.0001) and at PE (r = 0.912, p < 0.0001) as well as VE/Vo2 at AT (r = 0.942, p < 0.0001) and at PE (r = 0.781, p < 0.0002) and VE/Vco2 at AT (r = 0.995, p < 0.0001) and at PE (r = 0.943, p < 0.0001), respectively.ConclusionsOn adherence to standardized conditions, an excellent reproducibility existed for TWT, Vo2 (reflecting cardiac output), ventilation, and heart rate as well as derived parameters, rendering cardiopulmonary exercise testing a reliable means of quantification of heart failure as a prerequisite for enabling diagnostic or therapeutic decisions.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.