    [The study of AutoFlow role in volume controlled ventilation].

    • Yun-lin Song, Ying Li, Ye-wei Zhu, Qing-li Dou, Aierken Aierken, Rui-feng Chai, and Xiang-you Yu.
    • Department of Critical Care Unit, the First Affiliated Hospital of Xinjiang Medical University, Urumqi 830054, China.
    • Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2013 Jun 1; 25 (6): 327-30.

    ObjectiveTo evaluate the efficacy and safety of automatic variable flow rate (AutoFlow) for volume control ventilation through monitoring the number of ventilator alarm.MethodsForty-eight adult patients receiving the Drager Evita 4 ventilator with an expectation of more than 2 days duration were divided into two groups by randomly digital methods, each n=24. The patients in control group were received routinely mode with synchronized intermittent mandatory ventilation (SIMV), and the others in observation group were given SIMV and assist with AutoFlow. The midazolam and fentanyl was given to retain the Ramsay score 2-3 by continuous micro-pump. The ventilator alarm, blood gas analysis and respiratory function were recorded.ResultsThere were no significant differences in respiratory rate (RR), tidal volume (VT), positive end-expiratory pressure (PEEP), fraction of inspired oxygen (FiO₂), pH, arterial partial pressure of carbon dioxide (PaCO₂), arterial partial pressure of oxygen (PaO₂), oxygenation index (PaO₂/FiO₂), as well as sedative dose and time between two groups within 5 days of mechanical ventilation. Duration of mechanical ventilation in all patients was 164 days (3756 hours), and 78 days (1812 hours) in control group, 86 days (1944 hours) in observation group. The duration of mechanical ventilation in observation group was longer than that in control group [3 (1-15) days vs. 2 (1-28) days, P>0.05]. A total of 23 843 alarms were recorded, approximately 6 times/h, and 17 386 alarms in control group, averagely 9.6 times/h, 6457 alarms in the observation group, averagely 3.3 times/h. The number of ventilator alarm in observation group was less than that in control group (P<0.01). The number of airway pressure alarm in observation group was less than that in the control group [122 (8-1068) vs. 565 (13-1898), P<0.01]. There was no significant difference in sequential organ failure assessment (SOFA) score within 5 days between the two sets of mechanical ventilation. In the observation group ventilator-associated pneumonia (VAP) was occurred in 4 cases, and no pneumothorax happened, while in the control group there were 8 cases and 2 cases respectively. The mortality rate in intensive care unit (ICU) in observation group was lower than that in control group, but there was no statistical difference (25.0% vs. 37.5%, P>0.05).ConclusionsAutoFlow is confirmed be safe for volume control ventilation mode, and could significantly reduce the alarm of ventilator.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…