• Z Orthop Unfall · Jul 2009

    Clinical Trial

    [Dynamic gait analysis of blocked distal tibiofibular joint following syndesmotic complex lesions].

    • A Vasarhelyi, J Lubitz, A Zeh, D Wohlrab, W Hein, and T Mittlmeier.
    • Klinik und Poliklinik für Orthopädie und Physikalische Medizin, Universitätsklinikum Halle (Saale), Magdeburger Strasse 22, Halle (Saale). attila.vasarhelyi@medizin.uni-halle.de
    • Z Orthop Unfall. 2009 Jul 1; 147 (4): 439-44.

    AimDynamic gait analysis of blocked distal tibiofibular joint (TFJ) has not performed yet. This prospective study investigated patients treated for ankle fractures with combined syndesmotic complex lesions after surgery including tibiofibular positioning screw using CT data detecting fibular maltorsion and dynamic gait analysis.MethodPrepublished data of 61 patients after surgical block of TFJ were analysed for torsional deformity of the distal fibula with an especially developed novel CT method. 10 of these patients were selected for dynamic pedography (emed-SF4, Novel GmbH, Munich). The measurements were accomplished one and six weeks (with blocked TFJ) and four months (with deblocked TFJ) postoperatively.ResultsThe gait pattern of 10 pedographically investigated patients showed increased loads of the hindfoot as well as a load shift to the lateral midfoot. Four months postoperative significant differences of the plantar pressure pattern concerning the parameters force, pressure, impulse and contact time were not observed. The analysis of the foot progression angle (fpa) of the non operated feet demonstrated external rotation of 9,5 degrees in average. In comparison to the healthy side with tibiofibular positioning screw the operated feet were significantly internal rotated during the first two measurements. Patients with fibular torsional differences > 15 degrees showed not only with tibiofibular positioning screw but also after its removal a persistent difference of fpa in average of 5,6 degrees without external rotating retraction.ConclusionsThe temporary blockage of TFJ results into an altered pattern of dynamic plantar pressure distribution. A constant foot progression angle in relative internal rotation is registered. After removal of the positioning screw the recovered ligamentous structures allow retraction to the anatomic position. But, concerning fibular torsional differences > 15 degrees osseous fixation leads to alterated fpa presented as diminished external rotation of the foot of the formerly fractured ankle with consecutive dysfunction of the physiologic kinematic of movement and eventual provocation of posttraumatic arthritis.AimDynamic gait analysis of a blocked distal tibiofibular joint (TFJ) has not been performed yet. This prospective study investigated patients treated for ankle fractures with combined syndesmotic complex lesions after surgery including a tibiofibular positioning screw using CT data for detecting fibular maltorsion and dynamic gait analysis.MethodPrepublished data of 61 patients after surgical block of TFJ were analysed for torsional deformity of the distal fibula with an especially developed novel CT method. Ten of these patients were selected for dynamic pedography (emed-SF4, Novel GmbH, Munich). The measurements were accomplished one and six weeks (with blocked TFJ) and four months (with deblocked TFJ) postoperatively.ResultsThe gait patterns of 10 pedographically investigated patients showed increased loads of the hindfoot as well as a load shift to the lateral midfoot. Four months postoperative significant differences of the plantar pressure pattern concerning the parameters force, pressure, impulse and contact time were not observed. The analysis of the foot progression angle (fpa) of the non-operated feet demonstrated external rotation of 9,5 degrees in average. In comparison to the healthy side the operated feet with tibiofibular positioning screw were significantly internally rotated during the first two measurements. Patients with fibular torsional differences > 15 degrees showed not only with the tibiofibular positioning screw but also after its removal a persistent difference of fpa in average of 5.6 degrees without external rotating retraction.ConclusionsThe temporary blockage of the TFJ results into an altered pattern of dynamic plantar pressure distribution. A constant foot progression angle in relative internal rotation is registered. After removal of the positioning screw the recovered ligamentous structures allow retraction to the anatomic position. But, concerning fibular torsional differences > 15 degrees osseous fixation leads to alterated fpa presented as diminished external rotation of the foot of the formerly fractured ankle with consecutive dysfunction of the physiologic kinematic of movement and eventual provocation of posttraumatic arthritis.(c) Georg Thieme Verlag KG Stuttgart-New York.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.