• J R Army Med Corps · Dec 2017

    Comparative Study

    Biochemical analysis of cerebrospinal fluid in the laboratories of deployed medical treatment facilities: are Multistix 10 SG strip and iSTAT useful?

    • Bertrand Lefrere, J Plantamura, C Renard, F Ceppa, and H Delacour.
    • Département des laboratoires, Hôpital d'Instruction des Armées Bégin, Saint Mandé, France.
    • J R Army Med Corps. 2017 Dec 1; 163 (6): 397-400.

    IntroductionDuring military deployment, the diagnosis and the management of acute bacterial meningitis can be problematic, as deployed Medical Treatment Facilities (MTFs) often have a limited laboratory diagnostic capability. However, French Role 2 and 3 MTFs have point-of-care (POC) testing to perform urinary (Multistix 10 SG strip) and blood (iSTAT handheld analyser) biochemical testing mentioned in AMedP8.5. The purpose of this study was to compare the accuracy of this urine test strip and of the iSTAT CHEM8 and CG4 cartridges with a standard hospital bench top analyser in order to determine if these POC devices have a potential role in the biochemical analysis of cerebrospinal fluid (CSF protein, CSF glucose and CSF lactate, respectively).MethodsAgreement between the index methods and the reference methods (suitable kits on the Cobas 6 000 System) was evaluated by parallel testing of 30 CSF samples by both techniques. For CSF protein, agreement between the strip and the reference method was evaluated determining the κ coefficient. For CSF glucose and CSF lactate subgroups, least squares linear regressions were calculated and Bland-Altman analyses were performed.ResultsThe Multistix 10 SG strip can be used to make a semiquantitative determination of CSF protein. A good agreement between the strip and the reference method was observed (κ coefficient: 0.93 (IC95 0.82 to 1)). This strip is thus well adapted to demonstrate an elevation of CSF protein level as observed in acute bacterial meningitis. The iSTAT CHEM8 and CG4+ cartridges correlated well with the reference methods for the determination of CSF glucose and CSF lactate, respectively (r2>0.98) but exhibited a negative bias (∼ -7% and ∼ -15%, respectively).ConclusionsThe combined use of the Multistix 10 SG strip and of the iSTAT system appears to be an attractive solution for the biochemical investigation of CSF in medical treatment facilities with limited laboratory diagnostic capability.Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.