    AbstractA new, very fast, approach for calculations of the electromagnetic excitation field for MRI is presented. The calculation domain is divided in different homogeneous regions, where for each region a general solution is obtained by a summation of suitable basis functions. A unique solution for the electromagnetic field is found by enforcing the appropriate boundary conditions between the different regions. The method combines the speed of an analytical method with the versatility of full wave simulation methods and is validated in the pelvic region against FDTD simulations at 3 and 7 T and measurements at 3 T. The high speed and accurate reproduction of measurements and FDTD calculations are believed to offer large possibilities for multi-transmit applications, where it can be used for on-line control of the global and local electric field and specific absorption rate (SAR) in the patient. As an example the method was evaluated for RF shimming with the use of 7 T simulation results, where it was demonstrated that the magnetic excitation field could be homogenized, while both the local and average SAR were reduced by 38% or more.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…