-
Randomized Controlled Trial Comparative Study
Comparison of Two Levels of Pressure Support Ventilation on Success of Extubation in Preterm Neonates: A Randomized Clinical Trial.
- Roya Farhadi, Hamid Reza Lotfi, Abbas Alipour, Maryam Nakhshab, Vajiheh Ghaffari, and Seyyed Abbas Hashemi.
- . abbas.hashemi30@gmail.com.
- Glob J Health Sci. 2015 Jun 25; 8 (2): 240-7.
BackgroundPressure Support Ventilation (PSV) is one of the modes of mechanical ventilation that can be used alone as a weaning strategy in neonates. However, studies on the appropriate pressure level for this mode in neonates are limited.ObjectivesBecause the use of adequate pressure support in this mode, keeping the appropriate neonate's tidal volume, and preventing the respiratory complications, this study was aimed to compare extubation failure in the two levels of pressure support ventilation of 10 and 14 cmH2O when removing the neonates from the ventilator.Materials & MethodsIn this randomized clinical trial 50 premature infants of 27-37 weeks with respiratory distress syndrome (RDS) were under mechanical ventilation for at least 48 hours, were randomly assigned to two groups. One group was extubated in PSV mode with pressure of 14 cmH2O and the other with 10 cmH2O. Extubation failure rate and complications such as pneumothorax, death and respiratory parameters were compared in the two groups.ResultsTwenty five neonates in each group were assessed. Weaning time, extubation failure rate, and mean airway pressure was lesser in PSV of 10 cmH2O group than Level of 14 cmH2O and those differences were statistically significant (P<0.05). Difference between work of breathing, ventilation time, pneumothorax and mortality rate between two groups were not statistically significant (P>0.05).ConclusionThe results of our study show that extubation of the neonates using 10 CmH2O in PSV mode increases the success rate of extubation. Although when Volume- assured PSV can be used, it is more logical to use it for guaranteeing tidal volume, but using the appropriate level of pressure support when the PSV mode is used alone is inevitable and further studies are necessary to demonstrate the level of pressure in this mode.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*,_underline_or**bold**. - Superscript can be denoted by
<sup>text</sup>and subscript<sub>text</sub>. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3., hyphens-or asterisks*. - Links can be included with:
[my link to pubmed](http://pubmed.com) - Images can be included with:
 - For footnotes use
[^1](This is a footnote.)inline. - Or use an inline reference
[^1]to refer to a longer footnote elseweher in the document[^1]: This is a long footnote..