• Cochrane Db Syst Rev · Jan 2014

    Review

    Tracheal intubation with a flexible intubation scope versus other intubation techniques for obese patients requiring general anaesthesia.

    • Amanda Nicholson, Andrew F Smith, Sharon R Lewis, and Tim M Cook.
    • Faculty of Health and Medicine, Lancaster University, Lancaster, UK, LA1 4YG.
    • Cochrane Db Syst Rev. 2014 Jan 1;1:CD010320.

    BackgroundThe prevalence of obesity (body mass index (BMI) > 30 kg/m(2)) is increasing in both developed and developing countries, leading to a rise in the numbers of obese patients requiring general anaesthesia. Obese patients are at increased risk of anaesthetic complications, and tracheal intubation can be more difficult. Flexible intubation scopes (FISs) are recommended as an alternative method of intubation in these patients. Intubation with an FIS is considered an advanced method, requiring training and experience; therefore it may be underused in clinical practice. Patient outcomes following intubation with these scopes compared with other devices have not been systematically reviewed.ObjectivesWe wished to compare the safety and effectiveness of a flexible intubation scope (FIS) used for tracheal intubation in obese patients (BMI > 30 kg/m(2)) with other methods of intubation, including conventional direct laryngoscopy, non-standard laryngoscopy and the use of intubating supraglottic airway devices. We aimed to compare the frequency of complications, as well as process indicators, such as time taken for intubation and the proportion of first attempts that were successful, between groups using the different methods of intubation.Search MethodsWe searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE and two trial registers on 18 January 2013, and performed reference checking and citation searching and contacted study authors to identify additional studies.Selection CriteriaWe included randomized controlled trials (RCTs) of participants aged 16 years and older with a BMI > 30 kg/m(2) that had compared the use of an FIS for tracheal intubation with any one of three comparison groups: direct laryngoscopy; non-standard laryngoscopy (including indirect laryngoscopy using a videolaryngoscope (VLS) or a rigid or semi-rigid stylet); or intubation of supraglottic airway devices (SADs).Data Collection And AnalysisWe used standard methodological approaches expected by The Cochrane Collaboration, including independent review of titles, data extraction and risk of bias assessment by two investigators.Main ResultsThree eligible studies were identified, all comparing the use of an FIS with a VLS. All studies were small, with only 131 participants in total across all trials. It was impossible for the intubators to be unaware of the device used, so all studies were at high risk of performance and detection bias for outcomes related to intubation. Because of substantial differences in design between the studies, we did not combine their results in meta-analyses. The results for all outcomes were inconclusive, with no differences noted between FIS and VLS. Two studies with experienced intubators reported first attempt success rates greater than 70% in both groups and less than 5% of participants requiring a change of intubation device. No evidence was found of any difference in difficulty or time taken between FIS and VLS intubation. No serious complications or airway trauma was reported, so we were unable to address these outcomes. Bleeding was uncommon, occurring in less than 5% of participants, and we found no evidence that it was more likely in the FIS group. One small study with a novice intubator reported no successful intubations using an FIS and compared with the use of an intubating SAD and stylet, as well as with a VLS. With only five participants in each group, no conclusions can be drawn from these additional comparisons.Authors' ConclusionsThe evidence base is sparse, and the existing literature does not address the clinical questions of patient safety posed by this review. We are therefore unable to draw any conclusions on safety or effectiveness. More primary research is needed to investigate optimal intubation techniques in obese patients, and new studies should be powered to detect differences in complications and in success rates rather than process measures such as speed, which are of limited clinical importance.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…