- Fritz A Lerma, Bei Liu, Zhendong Wang, Byongyong Yi, Pradip Amin, Sandy Liu, Yuanming Feng, and Cedric X Yu.
- University of Maryland School of Medicine, Baltimore, MD 21201, USA. flerma@umm.edu
- Radiother Oncol. 2009 Oct 1; 93 (1): 18-24.
PurposeTo determine the expected benefit of image-guided online replanning over image-guided repositioning of localized prostate cancer intensity-modulated radiotherapy (IMRT).Materials And MethodsOn 10 to 11 CT scans of each of 10 early-stage prostate cancer patients, the prostate, bladder and rectum are manually segmented. Using a 3-mm PTV margin expansion from the CTV, an IMRT plan is made on the first CT scan of each patient. Online repositioning is simulated by recalculating the IMRT plan from the initial CT scan on the subsequent CT scans of each patient. For online replanning, IMRT is replanned twice on all CT scans, using 0-mm and 3-mm margins. The doses from subsequent CT images of each patient are then deformed to the initial CT anatomy using a mesh-based thin-plate B-spline deformation method and are accumulated for DVH and isodose review.ResultsPaired t-tests show that online replanning with 3-mm margins significantly increases the prostate volume receiving the prescribed dose over replanning with 0-mm margins (p-value 0.004); gives marginally better target coverage than repositioning with 3-mm margins(p-value 0.06-0.343), and reduces variations in target coverage over repositioning. Fractional volumes of rectum and bladder receiving 75%, 80%, 85%, 90%, and 95% (V75, V80, V85, V90, and V95) of the prescription dose are evaluated. V90 and V95 values for the rectum are 1.6% and 0.7 % for 3-mm margin replanning and 1% and 0.4 % for 0-mm margin replanning, with p-values of 0.010-0.011. No significant differences between repositioning and replanning with 3-mm margins are found for both the rectum and the bladder.ConclusionsImage-guided replanning using 3-mm margins reduces target coverage variations, and maintains comparable rectum and bladder sparing to patient repositioning in localized prostate cancer IMRT. Marginal reductions in doses to rectum and bladder are possible when planning margins are eliminated in the online replanning scenario. However, further reduction in treatment planning margins is not recommended.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.