• Anesthesia and analgesia · Apr 2022

    Validation of Continuous Noninvasive Blood Pressure Monitoring Using Error Grid Analysis.

    • Takashi Juri, Koichi Suehiro, Rieko Kanematsu, Kanae Takahashi, Yohei Fujimoto, Katsuaki Tanaka, and Takashi Mori.
    • From the Department of Anesthesiology, Osaka City University Graduate School of Medicine, Osaka, Japan.
    • Anesth. Analg. 2022 Apr 1; 134 (4): 773780773-780.

    BackgroundError grid analysis was recently proposed to compare blood pressure obtained by 2 measurement methods. This study aimed to compare continuous noninvasive blood pressure (CNBP) with invasive blood pressure (IBP) using the error grid analysis and investigate the confounding risk factors attributable to the differences between CNBP and IBP.MethodsSixty adult patients undergoing general anesthesia were prospectively enrolled. Simultaneous comparative data regarding CNBP and IBP were collected. The Bland-Altman analysis was conducted to compare CNBP and IBP for systolic blood pressure (SBP) and mean blood pressure (MBP; acceptable accuracy: mean bias <5 mm Hg; standard deviation <8 mm Hg). The clinical relevance of the discrepancies between CNBP and IBP was evaluated by the error grid analysis, which classifies the differences into 5 zones from "no risk" (A) to "dangerous risk" (E). Additionally, an ordinal logistic regression analysis was performed to evaluate the relationship between the risk zones for MBP, classified by the error grid analysis and covariates of interest.ResultsA total of 10,663 pairs of CNBP/IBP were finally analyzed. The Bland-Altman analysis showed an acceptable accuracy with a bias of -3.3 ± 5.6 mm Hg for MBP but a poor accuracy with a bias of 5.4 ± 10.5 mm Hg for SBP. The error grid analysis showed the proportions of zones A to E as 96.7%, 3.2%, 0.1%, 0%, and 0% for SBP, respectively, and 72.0%, 27.9%, 0.1%, 0%, and 0% for MBP, respectively. The finger cuff missed 23.9% of epochs when SBP <90 mm Hg and 55.3% of epochs when MBP <65 mm Hg. The ordinal logistic regression analysis revealed that older age (adjusted odds ratio for decade: 1.54, 95% confidence interval [CI], 1.15-2.08; P = .004) and length of time from the initiation of finger cuff inflation (adjusted odds ratio for 60 minutes: 1.40, 95% CI, 1.13-1.73; P = .002) were significant factors of being in a more dangerous zone of the error grid.ConclusionsThe error grid analysis revealed the larger clinical discrepancy between CNBP and IBP in MBP compared with that in SBP. Old age and longer finger cuff inflation time were significant factors of being in a more dangerous zone of the error grid, which could affect the hemodynamic management during surgery.Copyright © 2022 International Anesthesia Research Society.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…