• J. Thorac. Cardiovasc. Surg. · Jul 2023

    Meta Analysis

    Structural valve degeneration of bioprosthetic aortic valves: A network meta-analysis.

    • John J Squiers, N Bryce Robinson, Katia Audisio, William H Ryan, Michael J Mack, Mohamed Rahouma, Gianmarco Cancelli, Hristo Kirov, Torsten Doenst, Mario Gaudino, and J Michael DiMaio.
    • Department of Cardiothoracic Surgery, Baylor Scott & White The Heart Hospital, Plano, Tex.
    • J. Thorac. Cardiovasc. Surg. 2023 Jul 1; 166 (1): 525952-59.

    ObjectiveTo compare the rate of structural valve degeneration (SVD) following surgical aortic valve replacement associated with the Trifecta (TF) valve (St Jude Medical) versus other bioprosthetic valves.MethodsA systematic literature search was conducted for studies comparing durability of the TF prosthesis to other valve types, including Perimount (Edwards Lifesciences), Carpentier-Edwards Perimount Magna Ease (ME) (Edwards Lifesciences), and Mitroflow (LivaNova USA) after surgical aortic valve replacement. Random effect pairwise and network meta-analyses were performed to compare the incident rate ratio of the composite primary outcome of SVD or reintervention due to SVD.ResultsTen studies with 31,029 patients were included, of whom 6832 received TF, 19,023 received Perimount, 3514 received ME, and 713 received Mitroflow. When compared with TF, ME was associated with lower rates of SVD or reintervention for SVD (incident rate ratio, 0.13; 95% CI, 0.02-0.92; P = .04). Similarly, at network meta-analysis, when compared with TF, only ME was associated with significantly lower rates of SVD or reintervention for SVD (incident rate ratio, 0.13; 95% CI, 0.02-0.97). ME (incident rate ratio, 0.18; 95% CI, 0.07-0.47) and PM (incident rate ratio, 0.34; 95% CI, 0.12-0.98) were associated with significantly lower rate of all-cause reintervention when compared with TF. No differences in the other secondary outcomes were found.ConclusionsThe TF valve is associated with significantly higher rates of SVD or reintervention for SVD than the ME valve, but not the Mitroflow valve. The TF valve was also associated with higher rates of all-cause reintervention than ME and Perimount valves. The underlying mechanism(s) of these findings warrant further investigation.Copyright © 2022 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…