    PurposeTo evaluate the hemodynamic monitoring capability and safety of a single-use miniaturized transesophageal echocardiography (TEE) probe left in place in ventilated critically ill patients.MethodsThe probe was inserted in 94 patients and designed to be left in place for up to 72 h. Three views were obtained: the superior vena caval transverse, the mid-esophageal four-chamber, and the transgastric mid-papillary short-axis views. Observational data on the feasibility of insertion, complications, image quality, and influence on management were recorded and analyzed.ResultsNo failure of probe insertion was observed. The nasogastric tube had to be removed in 17 % of cases. Image quality was judged as adequate or optimal in 91/94 (97 %) of cases in the superior vena caval view, 89/94 (95 %) of cases in the four-chamber view, and 86/94 (91 %) of cases in the short-axis view. The duration of monitoring was 32 ± 23 h, allowing 2.8 ± 1.6 hemodynamic evaluations per patient that led to a mean of 1.4 ± 1.5 therapeutic changes per patient. Among the 263 hemodynamic assessments, 132 (50 %) had a direct therapeutic impact in 62 patients (66 %). Two patients developed lip ulceration from the probe, and two patients had self-limited gastric bleeding.ConclusionThe single-use miniaturized probe could be inserted in all patients. Image quality was acceptable in the majority of cases, and the information derived from the device was useful in making management decisions in patients with hemodynamic failure on ventilatory support. Further studies are needed to confirm the good tolerance and to compare the new device with other hemodynamic monitoring techniques.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.