• Anesthesia and analgesia · Aug 2022

    Multicenter Study Observational Study

    Outlying End-Tidal Carbon Dioxide During General Anesthesia Is Associated With Postoperative Pulmonary Complications: A Multicenter Retrospective Observational Study From US Hospitals Between 2010 and 2017.

    • Annemarie Akkermans, Judith A van Waes, Sachin Kheterpal, Wietze Pasma, Leif Saager, Aleda Thompson, and Wilton A van Klei.
    • From the Department of Anesthesiology, University Medical Center Utrecht, Utrecht University, Utrecht, the Netherlands.
    • Anesth. Analg. 2022 Aug 1; 135 (2): 341-353.

    BackgroundPostoperative pulmonary complications (PPCs) occur in up to 33% of patients who undergo noncardiothoracic surgery. Emerging evidence suggests that permissive hypercapnia may reduce the risk of lung injury. We hypothesized that higher intraoperative end-tidal carbon dioxide (Etco2) concentrations would be associated with a decreased risk of PPCs.MethodsThis retrospective, observational, multicenter study included patients undergoing general anesthesia for noncardiothoracic procedures (January 2010-December 2017). The primary outcome was PPC within 30 postoperative days. Secondary outcomes were PPC within 1 week, postoperative length of stay, and inhospital 30-day mortality. The association between these outcomes, median Etco2, and 4 time-weighted average area-under-the-curve (TWA-AUC) thresholds (<28, <35, <45, and >45 mm Hg) was explored using a multivariable mixed-effect model and by plotting associated risks.ResultsAmong 143,769 cases across 11 hospitals, 10,276 (7.1%) experienced a PPC. When compared to a baseline median Etco2 of 35 to 40 mm Hg, a median Etco2 >40 mm Hg was associated with an increase in PPCs within 30 days (median Etco2, 40-45 mm Hg; adjusted OR, 1.16 [99% confidence interval {CI}, 1.00-1.33]; P value = .008 and median Etco2, >45 mm Hg; OR, 1.64 [99% CI, 1.33-2.02]; P value < .001). The occurrence of any Etco2 value <28 mm Hg (ie, a positive TWA-AUC < 28 mm Hg) was associated with PPCs (OR, 1.40 [95% CI, 1.33-1.49]; P value < .001), mortality, and length of stay. Any Etco2 value >45 mm Hg (ie, a positive TWA-AUC >45 mm Hg) was also associated with PPCs (OR, 1.24 [95% CI, 1.17-1.31]; P < .001). The Etco2 range with the lowest incidence of PPCs was 35 to 38 mm Hg.ConclusionsBoth a very low (<28 mm Hg) and a high Etco2 (>45 mm Hg) were associated with PPCs within 30 days. The lowest PPC incidence was found in patients with an Etco2 of 35 to 38 mm Hg. Prospective studies are needed to clarify the relationship between postoperative PPCs and intraoperative Etco2.Copyright © 2022 International Anesthesia Research Society.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.