• J. Am. Coll. Surg. · Sep 2022

    Night Radiology Coverage for Trauma: Residents, Teleradiology, or Both?

    • Eric O Yeates, Areg Grigorian, Justine Chinn, Hayley Young, Jessica Colin Escobar, Justin Glavis-Bloom, Arash Anavim, Vahid Yaghmai, Ninh T Nguyen, Jeffry Nahmias, and UCI Trauma Radiology Study Group.
    • From the Department of Surgery (Yeates, Grigorian, Chinn, Young, Colin Excobar, Nguyen, Nahmias).
    • J. Am. Coll. Surg. 2022 Sep 1; 235 (3): 500509500-509.

    BackgroundOvernight radiology coverage for trauma patients is often addressed with a combination of on-call radiology residents (RR) and a teleradiology service; however, the accuracy of these 2 readers has not been studied for trauma. We aimed to compare the accuracy of RR versus teleradiologist interpretations of CT scans for trauma patients.Study DesignA retrospective analysis (March 2019 through May 2020) of trauma patients presenting to a single American College of Surgeons Level I trauma center was performed. Patients whose CT scans were performed between 10 pm to 8 am were included, because their scans were interpreted by both a RR and teleradiologist. Interpretations were compared with the final attending faculty radiologist's interpretation and graded for accuracy based on the RADPEER scoring system. Discrepancies were characterized as traumatic injury or incidental findings and missed findings or overcalls. Turnaround time was also compared.ResultsA total of 1,053 patients and 8,226 interpretations were included. Compared with teleradiologists, RR had a lower discrepancy (7.7% vs 9.0%, p = 0.026) and major discrepancy rate (3.8% vs 5.2%, p = 0.003). Among major discrepancies, RR had a lower rate of traumatic injury discrepancies (3.2% vs 4.4%, p = 0.004) and missed findings (3.4% vs 5.1%, p < 0.001), but a higher rate of overcalls (0.5% vs 0.1%, p < 0.001) compared with teleradiologists. The mean turnaround time was shorter for RR (51.3 vs 78.8 minutes, p < 0.001). The combination of both RR and teleradiologist interpretations had a lower overall discrepancy rate than RR (5.0% vs 7.7%, p < 0.001).ConclusionsThis study identified lower discrepancy rates and a faster turnaround time by RR compared with teleradiologists for trauma CT studies. The combination of both interpreters had an even lower discrepancy rate, suggesting this combination is optimal when an in-house attending radiologist is not available.Copyright © 2022 by the American College of Surgeons. Published by Wolters Kluwer Health, Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…