-
- Kazuya Tanaka, Takashi Yoshida, Kunihiko Hosoi, Naoki Okubo, Naoya Okada, and Kenji Takahashi.
- Department of Orthopaedic Surgery, Kyotango Municipal Kumihama Hospital, Kyoto, Japan; Department of Orthopaedic Surgery, North Medical Center, Kyoto Prefectural University of Medicine, Kyoto, Japan. Electronic address: m07056kt@jichi.ac.jp.
- Injury. 2022 Nov 1; 53 (11): 3781-3785.
IntroductionThe incidence of the fragility fractures of the pelvis (FFPs) has been increasing in recent years. Operative treatment is effective in patients who are unable to ambulate due to pain. Anterior subcutaneous internal fixation (ASIF) is a minimally invasive and stable fixation used to treat the FFPs, with few reported vascular complications. However, we experienced a case in which the rod directly pressed the common femoral artery (CFA).ObjectivesThe purpose of this study was to examine the relationship between the rod position as defined by ASIF and the CFA in the FFPs patients, and between BMI and the rod-to-CFA distance.Materials And MethodsPelvic measurements were performed in 47 patients with FFPs using trauma CT. We identified the anterior inferior iliac spine (AIIS) on both sides in axial CT images. Next, we performed a simulation study using the CT images, in which the virtual fixation rod was bent according to the shape of the patients' abdomen in the supine position. The shortest rod-to-CFA distance when the virtual rod was positioned directly above the AIIS in the CT image was measured. The correlation between body mass index (BMI) and the rod-to-CFA distance was measured.ResultsThe average shortest rod-to-CFA distance was 18.4 ± 11.1 mm, and the simulated rod compressed the CFA in three of the 47 cases (6.4%). A statistically significant positive correlation between BMI and the rod-to-CFA distance was found (r = 0.47, p = 0.001).ConclusionsThe course of the CFA should be confirmed before ASIF surgery, and if there is danger of compression of the CFA such as in patients with low BMI, the rod-to-AIIS distance should be adjusted to the optimal distance. However, considering the disadvantages, such as decreased stability of the fixation, when adjusting the rod-to-AIIS distance, and skin irritation and abrasion by the rod, ASIF is not recommended in cases in which the rod is close to the CFA.Copyright © 2022. Published by Elsevier Ltd.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.