• Eur J Trauma Emerg Surg · Jun 2023

    Multicenter Study

    Prospective randomized multicenter noninferiority clinical trial evaluating the use of TFN-advancedTM proximal femoral nailing system (TFNA) for the treatment of proximal femur fracture in a Chinese population.

    • Lidan Zhang, Zhijun Pan, Xiaohui Zheng, Qiugen Wang, Peifu Tang, Fang Zhou, Fan Liu, Bin Yu, Frankie K L Leung, Alex Wu, Suzanne Hughson, Zhuo Chen, Michael Blauth, Anthony Rosner, Charisse Sparks, and Manyi Wang.
    • Beijing Jishuitan Hospital, No.31 Xinjiekou East Road, Xicheng District, Beijing City, China.
    • Eur J Trauma Emerg Surg. 2023 Jun 1; 49 (3): 156115751561-1575.

    PurposeTo evaluate whether the 24-weeks postoperative fracture union rate for the investigational TFNA intramedullary nail was non-inferior compared to the control product PFNA-II.MethodsThe study was a prospective, randomized, single-blind, noninferiority dual-arm study drawing from 9 trauma centers across China, between November 2018 and September 2020, with follow-up measurements at 24 weeks after internal fixation. The full analysis data set (FAS [Intent-to-Treat]) was analyzed and is summarized here. The primary outcome was fracture union rate, a composite score combining clinical and radiographic assessment. Secondary endpoints comprised (a) clinical outcomes including (1) SF-12, (2) Harris Hip, and (3) EQ-5D Scores, (b) radiographic incidence of complications such as loosening or cut-out requiring revision, (c) revision rates, (d) reoperation rates, and (e) adverse events, including 24-weeks revision and reoperation rates.ResultsBoth TFNA and PFNA-II group fracture healing rates were 100% at 24 weeks; TFNA was therefore shown to be non-inferior to PFNA-II. With baseline data matched in all parameters except age in both the TFNA and PFNA-II groups, comparisons of union rates, SF-12, Harris Hip, and EQ-5D Scores yielded p values > 0.05 indicating no significant difference between the two groups, further supporting the noninferiority of TFNA. In both groups, revision and re-operation rates were 0, and the incidences of serious adverse events were 19.4% and 17.4%, respectively.ConclusionIn terms of fracture union rate at 24 weeks, the DePuy Synthes Trochanteric Fixation Nail Advanced (TFNA) was not inferior to the marketed Proximal Femoral Nail Antirotation (PFNA-II) device produced by the same manufacturer. Secondary and safety outcomes showed no significant differences between the two groups.RegistrationRegistration was completed at ClinicalTrials.gov NCT03635320.© 2023. The Author(s).

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…