• Resuscitation · Jun 2023

    Randomized Controlled Trial

    Mechanical ventilation with ten versus twenty breaths per minute during cardio-pulmonary resuscitation for out-of-hospital cardiac arrest: A randomised controlled trial.

    • Gerhard Prause, Philipp Zoidl, Michael Eichinger, Michael Eichlseder, Simon Orlob, Felix Ruhdorfer, Gabriel Honnef, MetnitzPhilipp G HPGHDivision of General Anaesthesiology, Emergency- and Intensive Care Medicine, Medical University of Graz, Graz, Austria., and Paul Zajic.
    • Division of General Anaesthesiology, Emergency- and Intensive Care Medicine, Medical University of Graz, Graz, Austria.
    • Resuscitation. 2023 Jun 1; 187: 109765109765.

    Aim Of The StudyThis study sought to assess the effects of increasing the ventilatory rate from 10 min-1 to 20 min-1 using a mechanical ventilator during cardio-pulmonary resuscitation (CPR) for out-of-hospital cardiac arrest (OHCA) on ventilation, acid-base-status, and outcomes.MethodsThis was a randomised, controlled, single-centre trial in adult patients receiving CPR including advanced airway management and mechanical ventilation offered by staff of a prehospital physician response unit (PRU). Ventilation was conducted using a turbine-driven ventilator (volume-controlled ventilation, tidal volume 6 ml per kg of ideal body weight, positive end-expiratory pressure (PEEP) 0 mmHg, inspiratory oxygen fraction (FiO2) 100%), frequency was pre-set at either 10 or 20 breaths per minute according to week of randomisation. If possible, an arterial line was placed and blood gas analysis was performed.ResultsThe study was terminated early due to slow recruitment. 46 patients (23 per group) were included. Patients in the 20 min-1 group received higher expiratory minute volumes [8.8 (6.8-9.9) vs. 4.9 (4.2-5.7) litres, p < 0.001] without higher mean airway pressures [11.6 (9.8-13.6) vs. 9.8 (8.5-12.0) mmHg, p = 0.496] or peak airway pressures [42.5 (36.5-45.9) vs. 41.4 (32.2-51.7) mmHg, p = 0.895]. Rates of ROSC [12 of 23 (52%) vs. 11 of 23 (48%), p = 0.768], median pH [6.83 (6.65-7.05) vs. 6.89 (6.80-6.97), p = 0.913], and median pCO2 [78 (51-105) vs. 86 (73-107) mmHg, p > 0.999] did not differ between groups.Conclusion20 instead of 10 mechanical ventilations during CPR increase ventilation volumes per minute, but do not improve CO2 washout, acidaemia, oxygenation, or rate of ROSC.Clinicaltrialsgov Identifier: NCT04657393.Copyright © 2023 Elsevier B.V. All rights reserved.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.