• J Clin Monit Comput · Apr 2023

    Review

    Reliability of stroke volume or pulse pressure variation as dynamic predictors of fluid responsiveness in laparoscopic surgery: a systematic review.

    • Jiaxin Chen, Shuhua Zhao, and Qianqian Zhu.
    • Department of Anesthesiology, The Seventh Affiliated Hospital of Sun Yat-Sen University, No. 628 Zhenyuan Road, Shenzhen, 518107, Guangdong, People's Republic of China.
    • J Clin Monit Comput. 2023 Apr 1; 37 (2): 379387379-387.

    AbstractThe reliability of stroke volume variation (SVV) and pulse pressure variation (PPV) in predicting fluid responsiveness during laparoscopic surgery remains unclear. We conducted the present systematic review to summarize the current evidence. We reviewed studies that investigated the reliability of SVV and PPV in laparoscopic surgery. Seven studies were included in the final analysis. Two studies demonstrated that the area under the receiver operating characteristic curve (AUROC) for SVV was less than 0.8, and five studies reported that the AUROC was > 0.8. The pooled AUROC for SVV and PPV was more than 0.8 with high heterogeneities between the included studies. Most individual studies have suggested that SVV and PPV are sufficiently reliable for predicting fluid responsiveness during laparoscopic surgery. However, the limited number of patients, varied apparatus used to define fluid responsiveness, diverse definitions of fluid responsiveness, and different fluids used to perform fluid challenges in the included studies render firm conclusions about SVV's and PPV's reliability impossible.© 2022. The Author(s), under exclusive licence to Springer Nature B.V.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…