• Anesthesia and analgesia · Dec 2023

    Randomized Controlled Trial

    Determination of the Optimal Volume of Programmed Intermittent Epidural Bolus When Combined With the Dural Puncture Epidural Technique for Labor Analgesia: A Random-Allocation Graded Dose-Response Study.

    • Fei Xiao, Han-Qing Yao, Jing Qian, Jia-Li Deng, Zheng-Fen Xu, Lin Liu, and Xin-Zhong Chen.
    • From the Department of Anesthesia, Jiaxing Women and Children's Hospital of Wenzhou Medical University, Jiaxing, China.
    • Anesth. Analg. 2023 Dec 1; 137 (6): 123312401233-1240.

    BackgroundThe dural puncture epidural (DPE) and the programmed intermittent epidural bolus (PIEB) techniques are recent innovations for labor analgesia. The optimal volume of PIEB during traditional epidural analgesia has been investigated previously but it is unknown whether these findings are applicable to DPE. This study aimed to determine the optimal volume of PIEB for effective labor analgesia after initiation of analgesia using DPE.MethodsParturients requesting labor analgesia received dural puncture with a 25-gauge Whitacre spinal needle and then had analgesia initiated with 15 mL of ropivacaine 0.1% with sufentanil 0.5 μg/mL. Analgesia was maintained using the same solution delivered by PIEB with boluses given at a fixed interval of 40 minutes starting 1 hour after the completion of the initial epidural dose. Parturients were randomized to 1 of 4 PIEB volume groups: 6, 8, 10, or 12 mL. Effective analgesia was defined as no requirement for a patient-controlled or manual epidural bolus for 6 hours after the completion of the initial epidural dose or until full cervical dilation. The PIEB volumes for effective analgesia in 50% of parturients (EV50) and 90% of parturients (EV90) were determined using probit regression.ResultsThe proportions of parturients with effective labor analgesia were 32%, 64%, 76%, and 96% in the 6-, 8-, 10-, and 12-mL groups, respectively. The estimated values for EV50 and EV90 were 7.1 (95% confidence interval [CI], 5.9-7.9) mL and 11.3 (95% CI, 9.9-15.2) mL, respectively. There were no differences in side effects, including hypotension, nausea and vomiting, and fetal heart rate (FHR) abnormalities among groups.ConclusionUnder the conditions of the study, after initiation of analgesia using DPE, the EV90 of PIEB for effective labor analgesia using ropivacaine 0.1% with sufentanil 0.5 μg/mL was approximately 11.3 mL.Copyright © 2023 International Anesthesia Research Society.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.