• J Clin Monit Comput · Apr 2024

    Observational Study

    Glucose measurements with accu check inform II versus hexokinase plasma method during surgery under general anesthesia, an observational cohort study.

    • Thomas Kaufmann, Robbert J Slingerland, Mireille A Edens, and Cornelis G Olthof.
    • Department of Anesthesiology, Isala, Zwolle, The Netherlands.
    • J Clin Monit Comput. 2024 Apr 1; 38 (2): 479485479-485.

    PurposeLimited research exists on translation of in-vitro glucose measurement interfering compounds to the in-vivo situation. We investigated whether Point-of-Care glucose measurements by Accu Chek Inform II (ACI II) were accurate to monitor glucose concentrations during surgery with general anesthesia by comparing with the reference laboratory hexokinase plasma glucose test.MethodPatients undergoing surgery with general anesthesia were included. Anesthesia was maintained with either Sevoflurane or Total intravenous anesthesia (TIVA). Prior to and after induction, blood glucose was measured with ACI II and the hexokinase test. Bland-Altman analysis was performed to assess method agreement. Subgroup analyses on glucose measurement differences per type of maintenance anesthesia were performed.ResultsThirty-nine patients were included, and 78 measurements were performed. All paired measurements had clinically acceptable agreement with a percentage error of 10.0% (95% CI 8.0 to 11.9). The mean difference (95% limits of agreement) between ACI II and hexokinase for all measurements was 0.0 mmol/L (-0.7 to 0.7 mmol/L). Before induction (n = 39), mean difference was -0.1 mmol/L (-0.6 to 0.4 mmol/L), and after induction (n = 39), mean difference was 0.1 mmol/L (-0.8 to 0.9 mmol/L). Further investigation showed the difference varied per test for patients receiving Sevoflurane compared to patients receiving TIVA (-0.2 ± 0.4 mmol/L vs. 0.4 ± 0.3 mmol/L, p < 0.001). Before and after induction, the difference between ACI II and hexokinase measurements increased for patients receiving Sevoflurane compared to patients receiving TIVA (0.4 ± 0.4 mmol/L vs. -0.4 ± 0.3 mmol/L, p < 0.001).ConclusionThe agreement between glucose measurements using ACI II and the reference laboratory hexokinase test was clinically acceptable with a percentage error of 10.0% (95% CI 8.0 to 11.9). The use of TIVA may negatively affect the measurement performance of the ACI II.© 2023. The Author(s), under exclusive licence to Springer Nature B.V.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.