• Journal of critical care · Dec 1998

    Review

    Continuous cardiac output and mixed venous oxygen saturation monitoring.

    • A Cariou, M Monchi, and J F Dhainaut.
    • Medical Intensive Care Unit, Cochin-Port Royal University Hospital, Paris, France.
    • J Crit Care. 1998 Dec 1; 13 (4): 198-213.

    AbstractContinuous assessment of cardiac output and SVO2 in the critically ill may be helpful in both the monitoring variations in the patient's cardiovascular state and in determining the efficacy of therapy. Commercially available continuous cardiac output (CCO) monitoring systems are based on the pulsed warm thermodilution technique. In vitro validation studies have demonstrated that this method provides higher accuracy and greater resistance to thermal noise than standard bolus thermodilution techniques. Numerous clinical studies comparing bolus with continuous thermodilution techniques have shown this technique similarly accurate to track each other and to have negligible bias between them. The comparison between continuous thermal and other cardiac output methods also demonstrates good precision of the continuous thermal technique. Accuracy of continuous oximetry monitoring using reflectance oximetry via fiberoptics has been assessed both in vitro and in vivo. Most of the studies testing agreement between continuous SVO2 measurements and pulmonary arterial blood samples measured by standard oximetry have shown good correlation. Continuous SVO2 monitoring is often used in the management of critically ill patients. The most recently designed pulmonary artery catheters are now able to simultaneously measure either SVO2 and CCO or SVO2 and right ventricular ejection fraction. This ability to view simultaneous trends of SVO2 and right ventricular performance parameters will probably allow the clinician to graphically see the impact of volume loading or inotropic therapy over time, as well as the influence of multiple factors, including right ventricular dysfunction, on SVO2. However, the cost-effectiveness of new pulmonary artery catheters application remains still questionable because no established utility or therapeutic guidelines are available.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…