-
Critical care medicine · Mar 2009
Predicting volume responsiveness by using the end-expiratory occlusion in mechanically ventilated intensive care unit patients.
- Xavier Monnet, David Osman, Christophe Ridel, Bouchra Lamia, Christian Richard, and Jean-Louis Teboul.
- AP-HP, Hôpital de Bicêtre, Service de Réanimation Médicale, Le Kremlin-Bicêtre, France. xavier.monnet@bct.aphp.fr
- Crit. Care Med. 2009 Mar 1;37(3):951-6.
ObjectiveDuring mechanical ventilation, inspiration cyclically decreases the left cardiac preload. Thus, an end-expiratory occlusion may prevent the cyclic impediment in left cardiac preload and may act like a fluid challenge. We tested whether this could serve as a functional test for fluid responsiveness in patients with circulatory failure.DesignProspective study.SettingMedical intensive care unit.PatientsThirty-four mechanically ventilated patients with shock in whom volume expansion was planned.InterventionA 15-second end-expiratory occlusion followed by a 500 mL saline infusion.MeasurementsArterial pressure and pulse contour-derived cardiac index (PiCCOplus) at baseline, during passive leg raising (PLR), during the 5-last seconds of the end-expiratory occlusion, and after volume expansion.Main ResultsVolume expansion increased cardiac index by >15% (2.4 +/- 1.0 to 3.3 +/- 1.2 L/min/m, p < 0.05) in 23 patients ("responders"). Before volume expansion, the end-expiratory occlusion significantly increased arterial pulse pressure by 15% +/- 15% and cardiac index by 12% +/- 11% in responders whereas arterial pulse pressure and cardiac index did not change significantly in nonresponders. Fluid responsiveness was predicted by an increase in pulse pressure >or=5% during the end-expiratory occlusion with a sensitivity and a specificity of 87% and 100%, respectively, and by an increase in cardiac index >or=5% during the end-expiratory occlusion with a sensitivity and a specificity of 91% and 100%, respectively. The response of pulse pressure and cardiac index to the end-expiratory occlusion predicted fluid responsiveness with an accuracy that was similar to the response of cardiac index to PLR and that was significantly better than the response of pulse pressure to PLR (receiver operating characteristic curves area 0.957 [95% confidence interval [CI:] 0.825-0.994], 0.972 [95% CI: 0.849-0.995], 0.937 [95% CI: 0.797-0.990], and 0.675 [95% CI: 0.497-0.829], respectively).ConclusionsThe hemodynamic response to an end-expiratory occlusion can predict volume responsiveness in mechanically ventilated patients.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*,_underline_or**bold**. - Superscript can be denoted by
<sup>text</sup>and subscript<sub>text</sub>. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3., hyphens-or asterisks*. - Links can be included with:
[my link to pubmed](http://pubmed.com) - Images can be included with:
 - For footnotes use
[^1](This is a footnote.)inline. - Or use an inline reference
[^1]to refer to a longer footnote elseweher in the document[^1]: This is a long footnote..