• Cochrane Db Syst Rev · Oct 2023

    Review

    Positioning for lumbar puncture in newborn infants.

    • Sara Pessano, Matteo Bruschettini, Marcus Glenton Prescott, and Olga Romantsik.
    • Neonatal Intensive Care Unit, Department Mother and Child, IRCCS Istituto Giannina Gaslini, Genoa, Italy.
    • Cochrane Db Syst Rev. 2023 Oct 23; 10 (10): CD015592CD015592.

    BackgroundLumbar puncture is a common invasive procedure performed in newborns for diagnostic and therapeutic purposes. Approximately one in two lumbar punctures fail, resulting in both short- and long-term negative consequences for the clinical management of patients. The most common positions used to perform lumbar puncture are the lateral decubitus and sitting position, and each can impact the success rate and safety of the procedure. However, it is uncertain which position best improves patient outcomes.ObjectivesTo assess the benefits and harms of the lateral decubitus, sitting, and prone positions for lumbar puncture in newborn infants.Search MethodsWe used standard, extensive Cochrane search methods. The latest search date was 24 January 2023.Selection CriteriaWe included randomized controlled trials (RCTs) and quasi-RCTs involving newborn infants of postmenstrual age up to 46 weeks and 0 days, undergoing lumbar puncture for any indication, comparing different positions (i.e. lateral decubitus, sitting, and prone position) during the procedure.Data Collection And AnalysisWe used standard Cochrane methods. We used the fixed-effect model with risk ratio (RR) and risk difference (RD) for dichotomous data and mean difference (MD) and standardized mean difference (SMD) for continuous data, with their 95% confidence intervals (CI). Our primary outcomes were successful lumbar puncture procedure at the first attempt; total number of lumbar puncture attempts; and episodes of bradycardia. We used GRADE to assess the certainty of evidence for each outcome.Main ResultsWe included five studies with 1476 participants. Compared to sitting position: lateral decubitus position may result in little to no difference in successful lumbar puncture procedure at the first attempt (RR 0.93, 95% CI 0.85 to 1.02; RD -0.04, 95% CI -0.09 to 0.01; I2 = 70% and 72% for RR and RD, respectively; 2 studies, 1249 infants, low-certainty evidence). None of the studies reported the total number of lumbar puncture attempts. Lateral decubitus position likely increases episodes of bradycardia (RR 1.72, 95% CI 1.08 to 2.76; RD 0.03, 95% CI 0.00 to 0.05; number needed to treat for an additional harmful outcome (NNTH) = 33; I2 = not applicable and 69% for RR and RD, respectively; 3 studies, 1279 infants, moderate-certainty evidence) and oxygen desaturation (RR 2.10, 95% CI 1.42 to 3.08; RD 0.06, 95% CI 0.03 to 0.09; NNTH = 17; I2 = not applicable and 96% for RR and RD, respectively; 2 studies, 1249 infants, moderate-certainty evidence). The evidence is very uncertain regarding the effect of lateral decubitus position on time to perform the lumbar puncture (MD 2.00, 95% CI -4.98 to 8.98; I2 = not applicable; 1 study, 20 infants, very low-certainty evidence). Lateral decubitus position may result in little to no difference in the number of episodes of apnea during the procedure (RR not estimable; RD 0.00, 95% CI -0.03 to 0.03; I2 = not applicable and 0% for RR and RD, respectively; 2 studies, 197 infants, low-certainty evidence). No studies reported apnea defined as number of infants with one or more episodes during the procedure. Compared to prone position: lateral decubitus position may reduce successful lumbar puncture procedure at first attempt (RR 0.75, 95% CI 0.63 to 0.90; RD -0.21, 95% CI -0.34 to -0.09; number needed to treat for an additional beneficial outcome = 5; I2 = not applicable; 1 study, 171 infants, low-certainty evidence). None of the studies reported the total number of lumbar puncture attempts or episodes of apnea. Pain intensity during and after the procedure was reported using a non-validated pain scale. None of the studies comparing lateral decubitus versus prone position reported the other critical outcomes of this review.Authors' ConclusionsWhen compared to sitting position, lateral decubitus position may result in little to no difference in successful lumbar puncture procedure at first attempt. None of the included studies reported the total number of lumbar puncture attempts. Furthermore, infants in a lateral decubitus position likely experience more episodes of bradycardia and oxygen desaturation, and there may be little to no difference in episodes of apnea. The evidence is very uncertain regarding time to perform lumbar puncture. Pain intensity during and after the procedure was reported using a pain scale that was not included in our prespecified tools for pain assessment due to its high risk of bias. Most study participants were term newborns, thereby limiting the applicability of these results to preterm babies. When compared to prone position, lateral decubitus position may reduce successful lumbar puncture procedure at first attempt. Only one study reported on this comparison and did not evaluate adverse effects. Further research exploring harms and benefits and the effect on patients' pain experience of different positions during lumbar puncture using validated pain scoring tool may increase the level of confidence in our conclusions.Copyright © 2023 The Cochrane Collaboration. Published by John Wiley & Sons, Ltd.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.