• Critical care medicine · Feb 2024

    Multicenter Study

    Deep Learning-Based Localization and Detection of Malpositioned Endotracheal Tube on Portable Supine Chest Radiographs in Intensive and Emergency Medicine: A Multicenter Retrospective Study.

    • Chih-Hung Wang, Tianyu Hwang, Yu-Sen Huang, Joyce Tay, Cheng-Yi Wu, Meng-Che Wu, Holger R Roth, Dong Yang, Can Zhao, Weichung Wang, and Chien-Hua Huang.
    • Department of Emergency Medicine, College of Medicine, National Taiwan University, Taipei, Taiwan.
    • Crit. Care Med. 2024 Feb 1; 52 (2): 237247237-247.

    ObjectivesWe aimed to develop a computer-aided detection (CAD) system to localize and detect the malposition of endotracheal tubes (ETTs) on portable supine chest radiographs (CXRs).DesignThis was a retrospective diagnostic study. DeepLabv3+ with ResNeSt50 backbone and DenseNet121 served as the model architecture for segmentation and classification tasks, respectively.SettingMulticenter study.PatientsFor the training dataset, images meeting the following inclusion criteria were included: 1) patient age greater than or equal to 20 years; 2) portable supine CXR; 3) examination in emergency departments or ICUs; and 4) examination between 2015 and 2019 at National Taiwan University Hospital (NTUH) (NTUH-1519 dataset: 5,767 images). The derived CAD system was tested on images from chronologically (examination during 2020 at NTUH, NTUH-20 dataset: 955 images) or geographically (examination between 2015 and 2020 at NTUH Yunlin Branch [YB], NTUH-YB dataset: 656 images) different datasets. All CXRs were annotated with pixel-level labels of ETT and with image-level labels of ETT presence and malposition.InterventionsNone.Measurements And Main ResultsFor the segmentation model, the Dice coefficients indicated that ETT would be delineated accurately (NTUH-20: 0.854; 95% CI, 0.824-0.881 and NTUH-YB: 0.839; 95% CI, 0.820-0.857). For the classification model, the presence of ETT could be accurately detected with high accuracy (area under the receiver operating characteristic curve [AUC]: NTUH-20, 1.000; 95% CI, 0.999-1.000 and NTUH-YB: 0.994; 95% CI, 0.984-1.000). Furthermore, among those images with ETT, ETT malposition could be detected with high accuracy (AUC: NTUH-20, 0.847; 95% CI, 0.671-0.980 and NTUH-YB, 0.734; 95% CI, 0.630-0.833), especially for endobronchial intubation (AUC: NTUH-20, 0.991; 95% CI, 0.969-1.000 and NTUH-YB, 0.966; 95% CI, 0.933-0.991).ConclusionsThe derived CAD system could localize ETT and detect ETT malposition with excellent performance, especially for endobronchial intubation, and with favorable potential for external generalizability.Copyright © 2023 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of the Society of Critical Care Medicine and Wolters Kluwer Health, Inc.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.