    The Accuracy of Readily Available Consumer-Grade Oxygen Saturation Monitors in Pediatric Patients.

    • Thomas Kovesi, Jeremy Saban, John Faissal Haddad, Deepti Reddy, Richard Webster, and Sharmila Udupa.
    • Drs Kovesi, Saban, and Udupa are affiliated with Children's Hospital of Eastern Ontario, University of Ottawa, Ottawa, Canada. Dr Haddad is affiliated with University of Calgary, Calgary, Canada. Ms Reddy and Dr Webster are affiliated with Children's Hospital of Eastern Ontario Research Institute, University of Ottawa, Ottawa, Canada. kovesi@cheo.on.ca.
    • Respir Care. 2024 Mar 27; 69 (4): 387394387-394.

    BackgroundPulse oximetry measurement is ubiquitous in acute health care settings in high-income countries and is familiar to any parent whose child has been treated in such a setting. Oximeters for home use are readily available online and are incorporated in several smartphones and smartwatches.MethodsWe wished to determine how accurate are oximeters available online that are designated for adult and pediatric use, and the saturation monitor integrated in a smartphone, when used in children, compared to reference, hospital-grade oximeters. We evaluated a fingertip oximeter marketed for children purchased online; an adult fingertip oximeter purchased online; the oximeter integrated in a smartphone; and reference, hospital-grade oximeters. Participants were < 18 y of age. Bland-Altman charts were generated, and the estimated root mean square error (EARMS) was calculated. Rates of failure to obtain a measurement, relationship between device and time to successful measurement, relationship between age and time to successful measurement, and relationship between error (vs the reference device) and age were evaluated for each consumer-grade device.ResultsWe measured SpO2 in 74 children between 0.1-17.0 y of age. Subjects weighing < 30 kg had a median (interquartile range [IQR]) age of 2 (1.0 month-1.4 y) months, and subjects weighing ≥ 30 kg had a median (IQR) age of 14.3 (11.9-16.2) y. Readings could not be obtained in 7.5, 0, and 38.8% of subjects using the pediatric, adult, and smartphone oximeters, respectively. The time to successful reading had a modest negative correlation with age with the inexpensive adult and pediatric oximeters. The inexpensive pediatric oximeter had an overall negative bias, with a mean difference from the reference device of -4.5% (SD 7.9%) and an error that ranged from > 8% to < 33% the reference device. The EARMS was 7.92%. The inexpensive adult oximeter demonstrated no obvious trend in error in the limited saturation range evaluated of 87-99%. The overall mean difference was -0.7% (SD 2.5%). EARMS was 2.5%. The smartphone oximeter underestimated SpO2 at saturations < 94% and overestimated SpO2 for saturations > 94%. Saturations could read as much as > 4%, or < 17%, than the reference oximeter. The mean difference was -2.9% (SD 5.2%). EARMS was 5.1%.ConclusionsOur findings suggest that the performance of consumer-grade devices varies considerably by both subject age and device. The pediatric fingertip device and smartphone application we tested are poorly suited for use in infants. The adult fingertip device we tested performed quite well in larger children with relatively normal oxygen saturations, and the pediatric fingertip device performed moderately well in subjects > 1 y of age who weighed < 30 kg. Given the vast number of devices available online and ever-changing technology, research to evaluate nonclinical oximeters will continue to be required.Copyright © 2024 by Daedalus Enterprises.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…