Comparative Study
The impact of a new CPR assist device on rate of return of spontaneous circulation in out-of-hospital cardiac arrest.
- Michael Casner, David Andersen, and S Marshal Isaacs.
- San Francisco Fire Department, San Francisco, California 94107, USA. michael.casner@sfgov.org
- Prehosp Emerg Care. 2005 Jan 1;9(1):61-7.
ObjectiveThe San Francisco Fire Department deployed an automated, load-distributing-band chest compression device (AutoPulse, Revivant Corporation) to evaluate its function in a large urban emergency medical services (EMS) service. A retrospective chart review was undertaken to determine whether the AutoPulse had altered short-term patient outcome, specifically, return of spontaneous circulation (ROSC).MethodsAutoPulse cardiopulmonary resuscitation (A-CPR) was used by paramedic captains responding to adult cardiac arrests with an average +/-SD response time of 15 +/- 5 minutes. The primary endpoint was patient arrival to an emergency department with measurable spontaneous pulses. The manual CPR comparison group was case-matched for age, gender, initial presenting electrocardiogram rhythm, and the number of doses of Advanced Cardiac Life Support medications as a proxy for treatment time. Matching was performed by an investigator blinded to outcome and treatment group.ResultsSixty-nine AutoPulse uses were matched to 93 manual-CPR-only cases. A-CPR showed improvement in the primary outcome when compared with manual CPR with any presenting rhythm (A-CPR 39%, manual 29%, p = 0.003). When patients were classified by first presenting rhythm, shockable rhythms showed no difference in outcome (A-CPR 44%, manual 50%, p = 0.340). Outcome was improved with A-CPR in initial presenting asystole and approached significance with pulseless electrical activity (PEA)(asystole: A-CPR 37%, manual 22%, p = 0.008; PEA: A-CPR 38%, manual 23%, p = 0.079).ConclusionThe AutoPulse may improve the overall likelihood of sustained ROSC and may particularly benefit patients with nonshockable rhythms. A prospective randomized trial comparing the AutoPulse with manual CPR in the setting of out-of-hospital sudden cardiac arrest is under way.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.