- Fai A Albuainain and Jie Li.
- Division of Respiratory Care, Department of Cardiopulmonary Sciences, Rush University, Chicago, Illinois. Ms Albuainain is affiliated with the Department of Respiratory Care, Imam Abdulrahman Bin Faisal University, Jubail, Saudi Arabia.
- Respir Care. 2024 Apr 23.
BackgroundOptimal aerosol delivery methods for spontaneously breathing patients with a tracheostomy remain unclear. Thus, we aimed to assess the impact of nebulizer placement, flow settings, and interfaces on aerosol delivery by using a vibrating mesh nebulizer and a jet nebulizer in line with unheated humidification.MethodsAn 8.0-mm tracheostomy tube was connected to the lung model that simulates adult breathing parameters via a collecting filter. Albuterol sulfate (2.5 mg/3 mL) was administered via a vibrating mesh nebulizer and a jet nebulizer, which was placed in line with unheated humidification provided by a large-volume nebulizer, with FIO2 set at 0.28, with gas flows of 2 L/min versus 6 L/min. Nebulizers were placed in line distal and proximal to the lung model by using a tracheostomy collar and a T-piece. Conventional nebulization was tested using a vibrating mesh nebulizer and a jet nebulizer directly connected to the tracheostomy tube bypassing the humidification device. The drug was eluted from the collecting filter and assayed with ultraviolet spectrophotometry (276 nm).ResultsDuring in-line nebulizer placement with unheated humidification, the inhaled dose was 2-4 times higher with a gas flow of 2 L/min than 6 L/min, regardless of nebulizer type, placement, or interface (all P < .05). At 6 L/min, the inhaled dose was higher with proximal than distal placement when using both interfaces, but, at 2 L/min, the inhaled dose was lower with proximal placement. With a jet nebulizer, the tracheostomy collar generated a higher inhaled dose at proximal placement compared with the T-piece, whereas the T-piece resulted in a higher inhaled dose than the tracheostomy collar with distal placement, regardless of the flow settings. Compared with conventional nebulization using a vibrating mesh nebulizer, an in-line vibrating mesh nebulizer with a large-volume nebulizer at 2 L/min had a similar inhaled dose, regardless of nebulizer placement and interface. In contrast, the in-line jet nebulizer was influenced by both placement and interface.ConclusionsAerosol delivery with an in-line vibrating mesh nebulizer and jet nebulizer with unheated humidification was affected by nebulizer placement, interface, and gas flow settings.Copyright © 2024 by Daedalus Enterprises.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.