• BMC anesthesiology · Mar 2024

    The effects of an IV fluid bolus on mitral annular velocity and the assessment of diastolic function: a prospective non-randomized study.

    • Sebastian Ayala, Orode Badakhsh, David Li, and Neal W Fleming.
    • Department of Anesthesiology & Pain Medicine, University of California, Davis, 4150 V Street Suite 1200 PSSB, Sacramento, CA, 95817, USA.
    • BMC Anesthesiol. 2024 Mar 26; 24 (1): 117117.

    BackgroundAbnormal diastolic function is an independent predictor of adverse postoperative outcomes. Mitral annular tissue Doppler velocity (e') is a key parameter for assessing diastolic function. The purpose of this study was to confirm that an acute increase in preload did not significantly impact the intraoperative measurement of e' and secondarily evaluate the impact of this acute intravascular volume increase on the clinical assessment of diastolic function using a previously described simplified algorithm.MethodsThis was a prospective, non-randomized study in adult patients undergoing elective cardiac surgeries requiring transesophageal echocardiographic monitoring, arterial pressure and Swan-Ganz catheter placements as part of the surgical procedure. Following baseline echocardiographic and hemodynamic measurements, 500 ml of crystalloid solution was infused over 10 min. Hemodynamic and echocardiographic measurements were repeated 5 min after fluid administration.ResultsComplete data sets were available from 84 of the 100 patients who were enrolled in this study. There was no significant change in the values of e'. The average baseline was 7.8 ± 2.0 cm/s (95%CI: 7.4, 8.2) and 8.1 ± 2.4 (95%CI: 7.6, 8.6) following the fluid bolus (p = 0.10). All hemodynamic variables associated with increased intravascular volume (central venous pressure, pulmonary arterial pressures and stroke volume variation) changed significantly. The overall distribution of diastolic function grades did not change following fluid administration (p = 0.69). However, there were many individual patient differences. When using this simplified algorithm, functional grading changed in 35 patients. Thirty of these 35 changes were only a single grade shift. 22 patients had worse functional grading after fluid administration while 13 had improved grading. Nine patients with normal diastolic function at baseline demonstrated diastolic dysfunction after fluid administration while 6 patients with baseline dysfunction normalized following the fluid bolus.ConclusionWe confirmed that e' is a robust measurement that is reproducible in the intraoperative setting despite variable vascular volume loading conditions, however, the clinical assessment of diastolic function was still altered in 42% of the patients following an intravenous fluid bolus.© 2024. The Author(s).

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…