• Critical care medicine · May 1992

    Validation of bedside measurements of absolute human renal blood flow by a continuous thermodilution technique.

    • G A Haywood, J T Stewart, P J Counihan, J F Sneddon, D Tighe, E D Bennett, and W J McKenna.
    • Department of Cardiological Sciences, St. George's Hospital Medical School, London, UK.
    • Crit. Care Med. 1992 May 1;20(5):659-64.

    Background And MethodsThere is a clinical need for a system that would allow rapid assessment of renal blood flow in patients with oliguric circulatory shock. A local, continuous thermodilution technique for the measurement of renal venous blood flow, using readily available equipment, was developed. To test the hypothesis that this system would allow measurement of renal blood flow in clinical situations, we compared simultaneous measurements made by the continuous thermodilution technique with measurements of: a) absolute flow measured by volumetric collection in an in vitro flow model; b) renal arterial blood flow measured by electromagnetic flow probe under changing hemodynamic conditions in nine pigs; and c) calculated renal blood flow derived from a clearance technique in 16 patients after cardiac catheterization. The technique utilizes a short-duration, constant infusion of room temperature normal saline into the renal vein via a retrograde thermodilution catheter, with measurement of flow at a thermistor 1 cm back from the tip of the catheter.ResultsThe method measured absolute blood flow in an in vitro model, with a correlation coefficient of .99 over blood flows ranging from 55 to 885 mL/min (r2 = .98). There was a .92 correlation coefficient with renal arterial blood flow measured by electromagnetic flow probe in a pig model (r2 = .85), and a .8 correlation with simultaneous measurement of renal blood flow by corrected iodohippurate clearance in humans (r2 = .64). Compared with electromagnetic flow probe measurements, a single measurement by the thermodilution technique would be accurate to within 80 mL/min in 95% of cases. Variability between individual measurements, expressed as the mean of the coefficient of variance for each patient, was 5.5 +/- 3.7%.ConclusionsThis technique is simple to use, requires only venous cannulation and injection of normal saline, and allows rapidly repeatable, immediately available measurements of renal blood flow in a wide range of clinical circumstances, including severe renal impairment or anuria.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.