    Accuracy of the Masimo Pronto-7® system in patients with left ventricular assist device.

    • Christian S Bruells, Ares K Menon, Rolf Rossaint, Andreas Goetzenich, Michael Czaplik, Norbert Zoremba, Rüdiger Autschbach, and Gereon Schaelte.
    • J Cardiothorac Surg. 2013 Jan 1;8:159.

    BackgroundThe Masimo Pronto-7® calculates hemoglobin (Hb) values using the pulsoximetry technique and a variety of mathematical algorithms analyzing the pulse waveform. Although this system has demonstrated a high level of accuracy in average patients, the performance might be altered in special patient populations. Regarding patients with left ventricular cardiac failure, a rotary blood pump generates a constant, continuous, non-pulsatile flow to improve effective cardiac output. Due to this alteration in both, blood flow and arterial blood pressure we hypothesized a reduced accuracy of the Masimo Pronto-7® to detect Hb in patients with left ventricular cardiac failure. To test our hypothesis, we evaluated the Pronto-7®SpHb system in outpatients after continuous-flow-left ventricular assist device (cf-LVAD) implantation (HeartMate II, Thoratec).Methods21 cf-LVAD outpatients from the Clinic for Cardiac, Thoracic and Vascular Surgery were investigated during routine follow up examinations. After venous blood samples were drawn, the Pronto-7® sensor was attached to one randomly selected finger of one hand. The collected SpHb data were compared with Hb values measured by our central laboratory. The difference between the methods was determined using Bland - Altman analysis. The study was registered in the DRKS (DRKS00004415).ResultsIn all cf-LVAD patients evaluated, the Pronto-7® successfully detected SpHb values. Using Bland - Altman analysis, a bias of 0.14 g/dl (95% upper and lower limits of agreement ± 2.76 g/dl) was calculated.ConclusionThe Pronto-7® overestimated the actual Hb value in cf-LVAD outpatients with the HeartMate II. Due to this, we conclude that the system is suitable for screening in routine examinations and further analysis can be performed if needed. However, its use as an emergency tool is questionable because of the increased inaccuracy when Hb values are critically low.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,706,642 articles already indexed!

We guarantee your privacy. Your email address will not be shared.