-
Comparative Study
Comparison of computed tomography perfusion and magnetic resonance imaging perfusion-diffusion mismatch in ischemic stroke.
- Bruce C V Campbell, Søren Christensen, Christopher R Levi, Patricia M Desmond, Geoffrey A Donnan, Stephen M Davis, and Mark W Parsons.
- Department of Medicine, The Melbourne Brain Centre at Royal Melbourne Hospital, University of Melbourne, Parkville, Victoria, Australia. bruce.campbell@mh.org.au
- Stroke. 2012 Oct 1;43(10):2648-53.
Background And PurposePerfusion imaging has the potential to select patients most likely to respond to thrombolysis. We tested the correspondence of computed tomography perfusion (CTP)-derived mismatch with contemporaneous perfusion-diffusion magnetic resonance imaging (MRI).MethodsAcute ischemic stroke patients 3 to 6 hours after onset had CTP and perfusion-diffusion MRI within 1 hour, before thrombolysis. Relative cerebral blood flow (relCBF) and time to peak of the deconvolved tissue residue function (Tmax) were calculated. The diffusion lesion (diffusion-weighted imaging) was registered to the CTP slabs and manually outlined to its maximal visual extent. Volumetric accuracy of CT-relCBF infarct core (compared with diffusion-weighted imaging) was tested. To reduce false-positive low CBF regions, relCBF core was restricted to voxels within a relative time-to-peak (relTTP) >4 seconds for lesion region of interest. The MR-Tmax >6 seconds perfusion lesion was automatically segmented and registered to CTP. Receiver-operating characteristic analysis determined the optimal CT-Tmax threshold to match MR-Tmax >6 seconds. Agreement of these CT parameters with MR perfusion-diffusion mismatch in coregistered slabs was assessed (mismatch ratio >1.2, absolute mismatch >10 mL, infarct core <70 mL).ResultsIn analysis of 49 patients (mean onset to CT, 213 minutes; mean CT to MR, 31 minutes), constraining relCBF <31% within the automated relTTP perfusion lesion region of interest reduced the median magnitude of volumetric error (vs diffusion-weighted imaging) from 47.5 mL to 15.8 mL (P<0.001). The optimal CT-Tmax threshold to match MR-Tmax >6 seconds was 6.2 seconds (95% confidence interval, 5.6-7.3 seconds; sensitivity, 91%; specificity, 70%; area under the curve, 0.87). Using CT-Tmax >6 seconds "penumbra" and relTTP-constrained relCBF "core," CT-based and MRI-based mismatch status was concordant in 90% (kappa=0.80).ConclusionsQuantitative CTP mismatch classification using relCBF and Tmax is similar to perfusion-diffusion MRI. The greater accessibility of CTP may facilitate generalizability of mismatch-based selection in clinical practice and trials.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*,_underline_or**bold**. - Superscript can be denoted by
<sup>text</sup>and subscript<sub>text</sub>. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3., hyphens-or asterisks*. - Links can be included with:
[my link to pubmed](http://pubmed.com) - Images can be included with:
 - For footnotes use
[^1](This is a footnote.)inline. - Or use an inline reference
[^1]to refer to a longer footnote elseweher in the document[^1]: This is a long footnote..