• J Clin Monit · Jan 1992

    Continuous noninvasive cardiac output as estimated from the pulse contour curve.

    • I Gratz, J Kraidin, A G Jacobi, N G deCastro, P Spagna, and G E Larijani.
    • Department of Anesthesiology, Medical College of Pennsylvania, Philadelphia 19129.
    • J Clin Monit. 1992 Jan 1;8(1):20-7.

    AbstractWe developed a noninvasive computer-based system for estimating continuous cardiac output by a modified pulse contour method using a finger pressure waveform. The method requires no individual patient calibration or baseline cardiac output. First, we calibrated the system in a "learn" group of 20 patients. The computer-based cardiac output was then compared with thermodilution cardiac output in 27 patients undergoing coronary artery bypass surgery. A total of 94 cardiac outputs were performed (three averaged per determination) at four predetermined time periods: preinduction, postinduction, prebypass, and postbypass. During determination of each thermodilution cardiac output, the pulse wave data were simultaneously recorded on cassette tape. The patients had cardiac outputs ranging from 2.9 to 6.4 L/min. The correlation coefficient was 0.75. The average thermodilution cardiac output was 4.50 (+/- 0.83 SD) L/min, while the cardiac output derived from the finger pressure wave was 4.48 (+/- 0.7 SD) L/min (95% confidence interval [CI] of difference, 0-3.2%). The mean difference between the two methods was 0.02 (+/- 0.55 SD) L/min. The 95% CI for the bias was 0.0001 to 0.036 L/min. The 95% CI for the lower limit of agreement was -1.12 to -1.06 L/min; the upper limit for the 95% CI was 1.09 to 1.16 L/min. The program demonstrated that information about cardiac output can be obtained by using the Finapres device (Ohmeda, Boulder, CO). The cardiac output values obtained by this continuous noninvasive technique were within +/- 20% of the simultaneous thermodilution values 87% of the time. This was true over the narrow range of cardiac outputs (2.9 to 6.4 L/min) and wide range of heart rates (45 to 140 beats/min).

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.