-
Critical care medicine · Nov 2006
Randomized Controlled Trial Multicenter StudyReduced burden of bacterial airway colonization with a novel silver-coated endotracheal tube in a randomized multiple-center feasibility study.
- Jordi Rello, Marin Kollef, Emili Diaz, Albert Sandiumenge, Yolanda del Castillo, Xavier Corbella, and Regina Zachskorn.
- Critical Care Department, Joan XXIII University Hospital, Tarragona, Spain. jrello.hj23.ics@gencat.net
- Crit. Care Med. 2006 Nov 1;34(11):2766-72.
ObjectiveTo assess the feasibility and safety of the respiratory infection control (RIC) device, a silver-coated endotracheal tube, and its effect on bacterial burden in the airways.DesignProspective, randomized, single-blind, multiple-center study.SettingThree hospitals in Spain and one in the United States.PatientsPatients were eligible adults who required mechanical ventilation for > or =24 hrs and did not have respiratory infections. One hundred forty-nine patients were intubated and analyzed for safety; 121 were intubated > or =24 hrs and analyzed for tube colonization; 67 had negative baseline quantitative endotracheal aspirates and were analyzed for quantitative endotracheal aspirates colonization.InterventionsIntubation with the RIC device or a control endotracheal tube.Measurements And Main ResultsThe RIC device was associated with delayed colonization on the tube compared with the control device at the threshold of ++, +++, or > or =10(4) colony-forming units/mL (p = .02, log-rank test; p = .10, Wilcoxon's test) and in quantitative endotracheal aspirates at > or =10(6) colony-forming units/mL (p = .08, log-rank test; p = .05, Wilcoxon's test). The RIC device was associated with reduced colonization rate by days on the tube (p = .04, Wilcoxon's test) and in quantitative endotracheal aspirates (p = .05, Wilcoxon's test) at the same thresholds. The RIC device was associated with lower maximal bacterial burden in tracheal aspirates for 7 days (mean log-transformed burden, 4.2 +/- 2.3 vs. 5.5 +/- 1.7 log colony-forming units/mL; p = .02, Wilcoxon's test). Other between-group differences favored the RIC device but were not significant. Five adverse events were considered device related, including three events in the RIC group and two events in the control group.ConclusionsIn this prospectively planned, preliminary analysis, the RIC device was feasible and well tolerated. Larger studies are needed to determine whether delayed colonization, reduced colonization rate, and decreased bacterial burden will decrease the incidence of ventilator-associated pneumonia.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.