• Cochrane Db Syst Rev · Jul 2014

    Review Meta Analysis

    Air versus saline in the loss of resistance technique for identification of the epidural space.

    • Pedro L Antibas, Paulo do Nascimento Junior, Leandro G Braz, João Vitor Pereira Doles, Norma S P Módolo, and Regina El Dib.
    • Department of Anaesthesiology, Hospital Sírio Libanês, São Paulo Serviços Médicos de Anestesia, Rua Moraes de Barros, 854 ap.41, São Paulo, São Paulo, Brazil, 04614-001.
    • Cochrane Db Syst Rev. 2014 Jul 18 (7): CD008938.

    BackgroundThe success of epidural anaesthesia depends on correct identification of the epidural space. For several decades, the decision of whether to use air or physiological saline during the loss of resistance technique for identification of the epidural space has been governed by the personal experience of the anaesthesiologist. Epidural block remains one of the main regional anaesthesia techniques. It is used for surgical anaesthesia, obstetrical analgesia, postoperative analgesia and treatment of chronic pain and as a complement to general anaesthesia. The sensation felt by the anaesthesiologist from the syringe plunger with loss of resistance is different when air is compared with saline (fluid). Frequently fluid allows a rapid change from resistance to non-resistance and increased movement of the plunger. However, the ideal technique for identification of the epidural space remains unclear.Objectives• To evaluate the efficacy and safety of both air and saline in the loss of resistance technique for identification of the epidural space.• To evaluate complications related to the air or saline injected.Search MethodsWe searched the Cochrane Central Register of Controlled Trials (CENTRAL) (2013, Issue 9), MEDLINE, EMBASE and the Latin American and Caribbean Health Science Information Database (LILACS) (from inception to September 2013). We applied no language restrictions. The date of the most recent search was 7 September 2013.Selection CriteriaWe included randomized controlled trials (RCTs) and quasi-randomized controlled trials (quasi-RCTs) on air and saline in the loss of resistance technique for identification of the epidural space.Data Collection And AnalysisTwo review authors independently assessed trial quality and extracted data.Main ResultsWe included in the review seven studies with a total of 852 participants. The methodological quality of the included studies was generally ranked as showing low risk of bias in most domains, with the exception of one study, which did not mask participants. We were able to include data from 838 participants in the meta-analysis. We found no statistically significant differences between participants receiving air and those given saline in any of the outcomes evaluated: inability to locate the epidural space (three trials, 619 participants) (risk ratio (RR) 0.88, 95% confidence interval (CI) 0.33 to 2.31, low-quality evidence); accidental intravascular catheter placement (two trials, 223 participants) (RR 0.90, 95% CI 0.33 to 2.45, low-quality evidence); accidental subarachnoid catheter placement (four trials, 682 participants) (RR 2.95, 95% CI 0.12 to 71.90, low-quality evidence); combined spinal epidural failure (two trials, 400 participants) (RR 0.98, 95% CI 0.44 to 2.18, low-quality evidence); unblocked segments (five studies, 423 participants) (RR 1.66, 95% CI 0.72 to 3.85); and pain measured by VAS (two studies, 395 participants) (mean difference (MD) -0.09, 95% CI -0.37 to 0.18). With regard to adverse effects, we found no statistically significant differences between participants receiving air and those given saline in the occurrence of paraesthesias (three trials, 572 participants) (RR 0.89, 95% CI 0.69 to 1.15); difficulty in advancing the catheter (two trials, 227 participants) (RR 0.91, 95% CI 0.32 to 2.56); catheter replacement (two trials, 501 participants) (RR 0.69, 95% CI 0.26 to 1.83); and postdural puncture headache (one trial, 110 participants) (RR 0.83, 95% CI 0.12 to 5.71).Authors' ConclusionsLow-quality evidence shows that results do not differ between air and saline in terms of the loss of resistance technique for identification of the epidural space and reduction of complications. Applicability might be compromised, as most of the results described in this review were obtained from parturient patients. This review underlines the need to conduct well-designed trials in this field. 

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…