• Critical care medicine · May 1996

    Albuterol delivery by metered-dose inhaler in a mechanically ventilated pediatric lung model.

    • S S Garner, D B Wiest, J W Bradley, B A Lesher, and D M Habib.
    • Department of Pharmaceutical Sciences, Medical University of South Carolina, Charleston 29425-0810, USA.
    • Crit. Care Med. 1996 May 1;24(5):870-4.

    ObjectivesTo assess albuterol delivery by metered-dose inhaler in a mechanically ventilated pediatric lung model and to determine the influence of the following variables on albuterol delivery: endotracheal tube diameter; type of spacer; humidification; and pulmonary mechanics.DesignProspective, in vitro, laboratory study.SettingResearch laboratory.InterventionsA model, consisting of a volume-cycled ventilator, pediatric breathing circuit, 4.0- or 6.0-mm endotracheal tube, and lung simulator, was assembled. Ventilator settings were: tidal volume 250 mL; FIO2 0.5; inspiration/expiration ratio 1:3; respiratory rate 25 breaths/min; positive end-expiratory pressure 3 cm H2O; temperature 35 degrees C; and a decelerating flow pattern, using dry and humidified air. Lung simulator compliance and resistance values were consistent with those values reported for healthy childeren (20 mL/cm H2O and 40 cm H20/L/sec) and children with pulmonary disease (10 mL/cm H2O and 60 cm H2O/L/sec). Pulmonary mechanics were verified with a pulmonary function diagnostic system. Ten metered-dose inhaler canisters were used to administer 2000 micrograms of albuterol, using either a collapsible or a rigid spacer. A circuit filter placed immediately proximal to the test lung collected drug exiting the endotracheal tube. The filter was rinsed with water and albuterol concentrations were determined by high-performance liquid chromatography. Each variable was tested in triplicate.Measurements And Main ResultsAlbuterol delivery was significantly (p < or = .05) greater for the 6.0-mm endotracheal tube, rigid spacer, dry air, and pulmonary disease mechanics by multifactor analysis of variance. Drug delivery in humidified air with pulmonary disease mechanics using the rigid chamber was 2.5 =/- 0.27% and 6.3 =/- 0.99% for the 4.0- and 6.0-mm endotracheal tubes, respectively.ConclusionsThese in vitro results suggest that pulmonary disease mechanics and a 6.0-mm endotracheal tube improve albuterol delivery. Future clinical investigations in intubated pediatric patients with pulmonary disease are needed to address the clinical significance of these results.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…