- Thomas C Mort.
- Department of Anesthesiology, Hartford Hospital, Hartford, CT 06015, USA. TMORT@harthosp.org
- J Clin Anesth. 2004 Nov 1;16(7):508-16.
Study ObjectiveTo determine the incidence and etiology of cardiopulmonary arrest during emergency intubation in the remote location by comparing two periods (1990-1995 vs. 1995-2002) at the same institution to assess whether immediate access to advanced airway devices and endotracheal tube-verifying devices altered the incidence of hypoxemia-driven cardiac arrest.DesignRetrospective review of a quality improvement (QI) database for emergency intubation outside the operating room (OR).Setting765-bed tertiary care, level 1 trauma center.Patients3035 critically ill patients suffering from cardiopulmonary, traumatic, septic, metabolic, or neurological-based deterioration and requiring emergency airway management.MeasurementsRate of cardiac arrest, as defined as asystole, bradycardia, or ventricular dysrhythmia with non-measurable blood pressure during or within 5 minutes of intubation, requiring cardiopulmonary resuscitation (CPR), were measured.Main Results60 cardiac arrests were documented (2%, or one per 50 cases), 83% of which were associated with profound hypoxemia (oxygen saturation <70%) during the airway procedure. Esophageal intubation was a frequent complication (n = 38; 63%), often leading to hypoxemia (97%) and regurgitation (67%). The overall rate of cardiac arrest was reduced 50% between the two time periods (2.8%: 1990-1995 period and 1.4%: 1995-2002 period). The relative risk estimate for complications in a match cohort contributing to the etiology of cardiac arrest included hypoxemia (4X), regurgitation (28X), aspiration (22X), bradycardia (23X) (all P < 0.003), and esophageal intubation (7X), P < 0.04). A total of 34% patients survived less than 24 hours and 31% survived to be discharged.ConclusionCardiac arrest during emergency tracheal intubation outside the OR is relatively common compared with the OR environment. Airway-related complications played a prominent role, either singly or in combination with the patient's underlying physiological state. Immediate access to advanced airway devices and endotracheal tube-verifying devices appear to have a significant impact on the incidence of hypoxemia-driven cardiac arrest.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.