    Transthoracic electrical bioimpedence cardiac output: comparison with multigated equillibrium radionuclide cardiography.

    • Arunodaya R Gujjar, K Muralidhar, Abhijit Bhandopadhyaya, T N Sathyaprabha, P Janaki, B K Mahalla, Ratan Gupta, Sanjay Banakal, and P S Jairaj.
    • National Institute of Mental Health and Neurosciences, Bangalore, 560029, India.
    • J Clin Monit Comput. 2010 Apr 1;24(2):155-9.

    IntroductionThoracic electrical bioimpedance (TEB) for measuring cardiac output (CO) is being explored increasingly as an alternative to pulmonary artery catheter. The major advantage of this technology is that it is non-invasive and easy to perform. Several studies have compared it to thermodilution cardiac output using PA catheter, with variable correlation. Multigated radionuclide equilibrium cardiography (RNEC) method of cardiac output measurement is known to be reliable.ObjectiveTo compare cardiac output measured by thoracic electrical bioimpdenace with that measured by multigated radionuclide equilibrium cardiography.Patients And MethodsCO studies were performed sequentially at a single sitting by TEB and RNEC methods among patients with cardiac symptoms referred for radionuclide study as part of their evaluation. TEB CO was measured by placing two pairs of electrodes on either side of neck and two other pairs on either side of the lower chest. Stroke volume was estimated from the sequential changes in transthoracic electrical bioimpedance induced by rhythmic aortic blood flow, using Kubicek equation. RNEC-CO was measured by intravenous injection of radio-active Technitium-tagged RBCs followed by ECG gated blood pool imaging over the chest (MUGA study). Bland-Altman analysis was used to compare the measurements.ResultsA total of 32 subjects with proven or suspected ischemic heart disease, but without overt cardiac failure, edema or arrhythmias were studied (M:F::26:6; mean age: 48 +/- 12 years). The mean TEB-CO was 3.54 +/- 1.052 l/min and mean RNEC-CO was 3.907 +/- 0.952 l/min. Correlation coefficient (r) for these measurements was 0.67 (p < 0.01), with bias: -0.421 l/min; precision: 1.557 l/min; and percentage error of measurement: 42.35%.ConclusionsThis study observed a moderate correlation between TEB and RNEC methods of CO measurement. Further studies are indicated to explore the relative utility of TEB in comparison with RNEC as well as other methods of CO measurement before considering its use in patients with ischemic heart disease.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…