-
- Giuseppe Paciocco, Elisabetta Uslenghi, Achille Bianchi, Gennaro Mazzarella, Giancarlo C Roviaro, Giuseppe Vecchi, and Sergio Harari.
- Department of Cardio-Thoracic and Respiratory Science, Second University of Naples, Naples, Italy.
- Chest. 2004 Jan 1;125(1):135-42.
BackgroundHigh-resolution CT (HRCT) scanning plays an important role in the diagnosis of diffuse cystic lung diseases (DCLDs). However, its role in the clinical evaluation of patients affected by DCLD has not yet been well-clarified. At present, pulmonary function tests are the only methods available for the evaluation of lung impairment due to these diseases, but their sensitivity and reliability are still limited.PurposeThe aim of this study was to correlate the quantitative score of cystic-aerial lesions obtained by a HRCT density mask (DM) software with pulmonary function data in DCLDs.MethodsSpirometry, lung volumes, diffusion capacity, arterial blood gas (ABG) analysis, 6-min walking test (6-MWT), and HRCT with DM quantitative evaluation were performed in a cohort of 25 patients (lymphangioleiomyomatosis [LAM], 13 patients; Langerhans cells histiocytosis [LCH], 12 patients). Linear regression was used for the statistical analysis. The sum and mean of the air-trapping percentages at three different levels of DM study (ie, aortic arch, left lower lobe bronchus origin, and 2 cm from the diaphragmatic muscle), and various functional parameters and exercise performance values were matched for the analysis.ResultsAn obstructive pattern was present in 13 patients (52%; LCH group, 8 patients; LAM group, 5 patients). A predominant restrictive pattern was detected only in three patients (12%; LCH group, two patients; LAM group, one patient). Nine patients (36%) walked < 350 m, and 14 of 23 patients (61%) had a significant decrease in arterial oxygen saturation during exercise (> 4 U). The results of DM quantitative study (sum and mean) significantly correlated with FVC (r = - 0.56; p < 0.001), FEV(1)/vital capacity (r = - 0.94; p < 0.002), midexpiratory phase of forced expiratory flow (r = - 0.84; p < 0.05), FEV(1) (r = - 0.82; p < 0.05), and diffusing capacity of the lung for carbon monoxide (r = - 0.82; p < 0.05), bronchial airway resistance (r = 0.79; p < 0.05), and distance walked on the 6-MWT (r = - 0.53; p < 0.05). No significant correlation was found with the results of ABG analysis.ConclusionsIn DCLDs, HRCT scans with quantitative assessment performed by a DM software showed a very good correlation with functional parameters. Therefore, DM could be considered, in combination with a complete functional assessment, in the initial evaluation of patients affected by DCLDs. However, further studies are needed to assess its usefulness in the follow-up of these patients.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*,_underline_or**bold**. - Superscript can be denoted by
<sup>text</sup>and subscript<sub>text</sub>. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3., hyphens-or asterisks*. - Links can be included with:
[my link to pubmed](http://pubmed.com) - Images can be included with:
 - For footnotes use
[^1](This is a footnote.)inline. - Or use an inline reference
[^1]to refer to a longer footnote elseweher in the document[^1]: This is a long footnote..