• Anesthesia and analgesia · Dec 2009

    Clinical Trial

    Stroke volume variation during acute normovolemic hemodilution.

    • Gudrun Kungys, David D Rose, and Neal W Fleming.
    • Department of Anesthesiology and Pain Medicine, University of California Davis, Davis, California, USA.
    • Anesth. Analg. 2009 Dec 1;109(6):1823-30.

    BackgroundThe intravascular volume of surgical patients should be optimized to avoid complications associated with both overhydration and underresuscitation. In patients undergoing intraoperative acute normovolemic hemodilution, we investigated whether stroke volume variation (SVV) derived from an arterial pressure-based cardiac output (CO) monitor system (FloTrac/Vigileo, Edwards Lifesciences, Irvine, CA) tracked the changes associated with blood removal and replacement. We further evaluated the correlations between SVV and 3-dimensional (3D) transesophageal echocardiographic (TEE) left ventricular (LV) volume measurements.MethodsTwenty-five patients had procedures during which acute normovolemic hemodilution was a planned part of the intraoperative management. We defined 7 measurement timepoints: baseline, after the removal of 5%, 10%, and 15% of the estimated blood volume (EBV) and after replacement with an equal volume of 6% hetastarch to -10%, -5%, and baseline EBV. At each timepoint, heart rate and systolic, diastolic, and mean arterial blood pressure were obtained from standard monitors, CO and SVV measurements were obtained from the FloTrac/Vigileo monitor, and TEE images were recorded for subsequent off-line reconstruction and determination of LV end-systolic and end-diastolic volumes. For statistical evaluations, we used a mixed models analysis of variance and Dunnett's test for post hoc comparisons with baseline values. Pearson's correlation was used to examine the relationships between SVV and LV volume.ResultsAnalysis of variance demonstrated no significant change in heart rate or mean arterial blood pressure over the duration of study. CO decreased from 4.9 +/- 0.3 to 4.5 +/- 0.3 L/min after removal of 15% of the EBV and then increased to a final value of 5.4 +/- 0.3 L/min after replacement of 15% of the EBV. SVV increased from 9.2% +/- 0.9% to 20.3% +/- 2.0% (P < 0.001) after removal of 15% of the EBV and returned to a final value of 7.2% +/- 0.9% after replacement of 15% of the EBV. The indexed LV end-diastolic volume decreased from 42.1 +/- 8.3 to 36.9.3 +/- 8.3 mL/m(2) (P < 0.001) after removal of 15% of the EBV and then returned to a final volume of 45.9 +/- 10.3 mL/m(2) after replacement of 15% of the EBV. The measurements of SVV correlated inversely with the 3D TEE LV volume measurements.ConclusionsThe SVV derived from the FloTrac/Vigileo system changes significantly as blood is removed and replaced during hemodilution. These changes correlate with 3D TEE measurements of LV volume. The utility of SVV in guiding optimization of intravascular volume merits further study.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.