- Christopher Munoz-Bendix, Kerim Beseoglu, and Rainer Kram.
- Department of Neurosurgery, Medical Faculty, Heinrich-Heine-University Düsseldorf, Moorenstrasse 5, 40225, Düsseldorf, Germany. christopher.munoz@med.uni-duesseldorf.de.
- Crit Care. 2015 Jan 1; 19: 381.
IntroductionAcute respiratory distress syndrome (ARDS) with concomitant impairment of oxygenation and decarboxylation represents a complex problem in patients with increased intracranial pressure (ICP). Permissive hypercapnia is not an option to obtain and maintain lung-protective ventilation in the presence of elevated ICP. Pumpless extracorporeal lung assist (pECLA) devices (iLA Membrane Ventilator; Novalung, Heilbronn, Germany) can improve decarboxylation without aggravation associated with invasive ventilation. In this pilot series, we analyzed the safety and efficacy of pECLA in patients with ARDS and elevated ICP after severe traumatic brain injury (TBI).MethodsThe medical records of ten patients (eight male, two female) with severe ARDS and severe TBI concurrently managed with external ventricular drainage in the neurointensive care unit (NICU) were retrospectively analyzed. The effect of pECLA on enabling lung-protective ventilation was evaluated using the difference between plateau pressure and positive end-expiratory pressure, defined as driving pressure (ΔP), during the 3 days preceding the implant of pECLA devices until 3 days afterward. The ICP threshold was set at 20 mmHg. To evaluate effects on ICP, the volume of daily cerebrospinal fluid (CSF) drainage needed to maintain the set ICP threshold was compared pre- and postimplant.ResultsThe ΔP values after pECLA implantation decreased from a mean 17.1 ± 0.7 cm/H2O to 11.9±0.5 cm/H2O (p = 0.011). In spite of this improved lung-protective ventilation, carbon dioxide pressure decreased from 46.6 ± 3.9 mmHg to 39.7 ± 3.5 mmHg (p = 0.005). The volume of daily CSF drainage needed to maintain ICP at 20 mmHg decreased significantly from 141.5 ± 103.5 ml to 62.2 ± 68.1 ml (p = 0.037).ConclusionsFor selected patients with concomitant severe TBI and ARDS, the application of pECLA is safe and effective. pECLA devices improve decarboxylation, thus enabling lung-protective ventilation. At the same time, potentially detrimental hypercapnia that may increase ICP is avoided. Larger prospective trials are warranted to further elucidate application of pECLA devices in NICU patients.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.