-
J. Thorac. Cardiovasc. Surg. · Nov 2000
Midterm follow-up of patients who underwent removal of a left ventricular assist device after cardiac recovery from end-stage dilated cardiomyopathy.
- R Hetzer, J H Müller, Y G Weng, M Loebe, and G Wallukat.
- Deutsches Herzzentrum, Berlin, Germany. hetzer@dhzb.de
- J. Thorac. Cardiovasc. Surg. 2000 Nov 1;120(5):843-53.
ObjectiveCardiac recovery in end-stage idiopathic dilated cardiomyopathy recently occurred after temporary support with a left ventricular assist device. We report the case histories of patients who underwent removal of the device more than 4 years ago.MethodsSince June 1994, 23 patients with end-stage idiopathic dilated cardiomyopathy who were supported by a left ventricular assist device or biventricular assist device for 1 to 26 months (mean, 6 months) underwent removal of the device after complete or extensive cardiac recovery, as revealed by echocardiography.ResultsSeven patients (group A) had recurrent cardiac failure after 4 to 24 months. Transplantation was performed in 6 patients, and one died while on the waiting list. Three patients died of noncardiac causes within a period of 4 months and 3 days after removal of the assist device. Stable cardiac recovery occurred in 13 patients (group B) for 3 to 49 months (mean, 23 months). At the time of implantation, there were no significant differences between the groups with regard to age, hemodynamics, left ventricular ejection fraction, left ventricular internal diameter in diastole, and autoantibody levels. The increase of ejection fraction and the decrease of left ventricular internal diameter in diastole after 2 months were highly significant. The patients in group A had longer histories of heart failure and first cardiac symptoms and duration of assist when compared with group B. Group B demonstrated a quicker cardiac recovery on the assist device, and thus support was shorter. Also, the degree of recovery at assist device explantation was more complete in group B. The age at the time of device placement was the only influencing factor for duration on the assist device. The probability of recurrence of heart failure was influenced by the duration of heart failure.ConclusionsIn selected patients with idiopathic dilated cardiomyopathy, lasting recovery can be achieved after unloading with a left ventricular assist device. Lasting cardiac recovery seems to be related to functional normalization and a more rapid recovery during the unloading period.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.