-
Randomized Controlled Trial Comparative Study Clinical Trial
The effect of a voice assist manikin (VAM) system on CPR quality among prehospital providers.
- David Hostler, Henry Wang, Kevin Parrish, Thomas E Platt, and Guy Guimond.
- Department of Emergency Medicine, Affiliated Emergency Medicine Residency, University of Pittsburgh, Pittsburgh, Pennsylvania 15213, USA. hostlerdp@upmc.edu
- Prehosp Emerg Care. 2005 Jan 1;9(1):53-60.
UnlabelledNumerous studies have documented poor cardiopulmonary resuscitation (CPR) performance among prehospital providers during both simulated and actual resuscitations. Previous studies have shown that a real-time, voice assist manikin (VAM) system may improve CPR performance.ObjectiveTo determine whether VAM prompting would improve CPR performance by prehospital providers during simulated resuscitation.MethodsIn this prospective, randomized, crossover design, 114 prehospital providers performed two 3-minute sessions of one-rescuer CPR on a VAM-resuscitation manikin: one round with the VAM feature turned on and one with the feature turned off. The primary outcomes were measured at 15-second intervals and included the fraction of correct compressions, the mean compression depth, the fraction of correct ventilations, and the mean ventilation tidal volume. Generalized estimating equations were used to analyze the repeated measures.ResultsThe VAM prompting was not directly associated with correct compressions during one-rescuer CPR in a cohort of subjects naïve to the system. However, the general decay in correct compressions seen over 3 minutes was attenuated with VAM prompting. Neither the compression depth nor the decay in compression depth over time was affected by VAM prompting. In contrast, VAM prompting did affect the fraction of correct ventilations and attenuated the time-dependent decline in correct ventilations in tidal volume.ConclusionsUse of VAM did not directly improve compression or ventilation rate or quality in this cohort of prehospital providers. However, use of VAM did prevent decay of compression and ventilation performance over time.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.