• Resuscitation · Jan 2016

    Filtering mechanical chest compression artefacts from out-of-hospital cardiac arrest data.

    • E Aramendi, U Irusta, U Ayala, H Naas, J Kramer-Johansen, and T Eftestøl.
    • Communications Engineering Department, University of the Basque Country UPV/EHU, Alameda Urquijo S/N, 48013 Bilbao, Spain. Electronic address: elisabete.aramendi@ehu.eus.
    • Resuscitation. 2016 Jan 1; 98: 41-7.

    AimFiltering techniques to remove manual compression artefacts from the ECG have not been incorporated to defibrillators to diagnose the rhythm during cardiopulmonary resuscitation. Mechanical and manual compression artefacts may be very different. The aim of this study is to characterize the compression artefact caused by the LUCAS 2 device and to evaluate whether filtering the LUCAS 2 artefact results in an accurate rhythm analysis.MethodsA dataset of 1045 segments were obtained from 230 out-of-hospital cardiac arrest (OHCA) patients after LUCAS 2 activation. Rhythms were 201 shockable, 270 asystole and 574 organized. Segments during asystole were used to characterize the artefact in time and frequency domains. Three filtering methods, a comb filter and two adaptive filters, were used to remove the mechanical compression artefact. The filtered ECG was then diagnosed with a shock decision algorithm from a defibrillator.ResultsWhen compared to the manual compression artefact, the LUCAS 2 artefact presented a similar amplitude (1.2 mV, p-value 0.26), fixed frequency (101.7 min(-1)), more harmonic components, smaller spectral dispersion, and a more regular waveform (p-val <3 × 10(-7)). The sensitivity (SE) and specificity (SP) before filtering the LUCAS 2 artefact were 52.8% (90% low CI, 46.0%) and 81.5% (79.0%), respectively. For the best filter, SE and SP after filtering were 97.9% (95.7%) and 84.1% (82.0%), respectively. Optimal filters require more harmonics and smaller bandwidths than for manual compressions.ConclusionFiltering resulted in a large increase in SE and small increase in SP. Despite differences in artefact characteristics between manual and mechanical compressions, filtering the LUCAS 2 compression artefact results in SE/SP values comparable to those obtained for manual compression artefacts. The SP is still below the 95% recommended by the American Heart Association.Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.