Intensive care medicine · Nov 2009
Comparative StudyDetection of carbon dioxide thresholds using low-flow sidestream capnography in ventilated preterm infants.
- Emmanuel Lopez, Sophie Grabar, Alexandre Barbier, Baruch Krauss, Pierre-Henri Jarreau, and Guy Moriette.
- Service de Médecine néonatale, Groupe Hospitalier Cochin-Saint Vincent de Paul, AP-HP, 123 Bd du Port-Royal, 75014 Paris, France. emmanuel.lopez@cch.aphp.fr
- Intensive Care Med. 2009 Nov 1;35(11):1942-9.
BackgroundMonitoring CO2 levels in preterm infants receiving mechanical ventilation is designed to avoid the harmful consequences of hypocapnia or hypercapnia. Capnography is of questionable accuracy for monitoring PCO2 in preterm infants.ObjectivesTo determine the accuracy of sidestream capnography in ventilated preterm infants by comparing end-tidal carbon dioxide (EtCO2) values to mixed venous carbon dioxide pressure (PvCO2) and to transcutaneous carbon dioxide pressure (TcPCO2).MethodsSimultaneous recordings of EtCO2, TcPCO2 and PvCO2 in 37 ventilated preterm infants. The PvCO2-EtCO2 gradient was calculated. The Bland-Altman technique and the intra-class correlation coefficient (ICC) were used to assess agreement between methods. The area under the curve (AUC) was calculated.ResultsNinety-nine EtCO2/PvCO2 pairs were studied from 37 preterm infants with a mean gestational age of 27.7 +/- 1.9 weeks and a mean birth weight of 1,003 +/- 331 g. The mean PvCO2-EtCO2 gradient was 11.2 +/- 8.0 mmHg, and the ICC was 0.28. The mean PvCO2-TcPCO2 gradient was 0 +/- 7.8 mmHg, and the ICC was 0.78. AUCs for EtCO2 and TcPCO2 were similar in detecting high or low PvCO2.ConclusionDespite an insufficient correlation between EtCO2 and PvCO2, capnography was able to detect low and high CO2 warning levels with a similar efficacy to that of TcPCO2, and may therefore be of clinical interest.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.