-
- Wendy W Chapman, John N Dowling, and Michael M Wagner.
- Center for Biomedical Informatics, Department of Medicine, University of Pittsburgh, Pittsburgh, PA, USA. chapman@cbmi.pitt.edu
- Ann Emerg Med. 2005 Nov 1;46(5):445-55.
Study ObjectiveElectronic surveillance systems often monitor triage chief complaints in hopes of detecting an outbreak earlier than can be accomplished with traditional reporting methods. We measured the accuracy of a Bayesian chief complaint classifier called CoCo that assigns patients 1 of 7 syndromic categories (respiratory, botulinic, gastrointestinal, neurologic, rash, constitutional, or hemorrhagic) based on free-text triage chief complaints.MethodsWe compared CoCo's classifications with criterion syndromic classification based on International Classification of Diseases, Ninth Revision (ICD-9) discharge diagnoses. We assigned the criterion classification to a patient based on whether the patient's primary diagnosis was a member of a set of ICD-9 codes associated with CoCo's 7 syndromes. We tested CoCo's performance on a set of 527,228 chief complaints from patients registered at the University of Pittsburgh Medical Center emergency department (ED) between 1990 and 2003. We performed a sensitivity analysis by varying the ICD-9 codes in the criterion standard. We also tested CoCo on chief complaints from EDs in a second location (Utah).ResultsApproximately 16% (85,569/527,228) of the patients were classified according to the criterion standard into 1 of the 7 syndromes. CoCo's classification performance (number of cases by criterion standard, sensitivity [95% confidence interval (CI)], and specificity [95% CI]) was respiratory (34,916, 63.1 [62.6 to 63.6], 94.3 [94.3 to 94.4]); botulinic (1,961, 30.1 [28.2 to 32.2], 99.3 [99.3 to 99.3]); gastrointestinal (20,431, 69.0 [68.4 to 69.6], 95.6 [95.6 to 95.7]); neurologic (7,393, 67.6 [66.6 to 68.7], 92.7 [92.6 to 92.8]); rash (2,232, 46.8 [44.8 to 48.9], 99.3 [99.3 to 99.3]); constitutional (10,603, 45.8 [44.9 to 46.8], 96.6 [96.6 to 96.7]); and hemorrhagic (8,033, 75.2 [74.3 to 76.2], 98.5 [98.4 to 98.5]). The sensitivity analysis showed that the results were not affected by the choice of ICD-9 codes in the criterion standard. Classification accuracy did not differ on chief complaints from the second location.ConclusionOur results suggest that, for most syndromes, our chief complaint classification system can identify about half of the patients with relevant syndromic presentations, with specificities higher than 90% and positive predictive values ranging from 12% to 44%.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.