Pediatric pulmonology · Apr 2012
End-tidal carbon dioxide monitoring in very low birth weight infants: correlation and agreement with arterial carbon dioxide.
- Daniele Trevisanuto, Stephanie Giuliotto, Francesco Cavallin, Nicoletta Doglioni, Silvia Toniazzo, and Vincenzo Zanardo.
- Pediatric Department, Medical School, University of Padua, Azienda Ospedaliera Padova, Padua, Italy. trevo@pediatria.unipd.it
- Pediatr. Pulmonol. 2012 Apr 1;47(4):367-72.
ObjectiveWe aimed to determine the correlation and the agreement between end-tidal carbon dioxide (ETCO(2)) and partial pressure of arterial carbon dioxide (PaCO(2) ) in very low birth weight infants (VLBWI); furthermore, we assessed factors that could affect the ETCO(2)-PaCO(2) relationship.MethodsSimultaneous end-tidal and arterial CO(2) pairs were obtained from ventilated VLBWI who were monitored by mainstream capnography and had umbilical arterial catheter. Correlation and agreement between ETCO(2) and PaCO(2) were evaluated by using Spearman test and Bland-Altman method, respectively.ResultsA total of 143 simultaneous ETCO(2)-PaCO(2) pairs were analyzed from 45 ventilated VLBWI. There was a significant correlation (r = 0.69; P < 0.0001) between ETCO(2) and PaCO(2) values. The ETCO(2) value was lower than the corresponding PaCO(2) value in 94% pairs, with a mean bias of 13.5 ± 8.4 mmHg (95% agreement levels, -3.0 to 29.9 mmHg). Mean PaCO(2)-ETCO(2) bias was similar between ELBWI (13.1 ± 7.7 mmHg; 95% agreement levels, -1.9 and 28.2 mmHg) and infants with birth weight 1,001-1,500 g (14.8 ± 9.7 mmHg; 95% agreement levels -4.3 and 33.8 mmHg). The bias between ETCO(2) and PaCO(2) was significantly increased with increasing FiO(2), mean airway pressure and oxygenation index. Within each patient, there was a positive correlation (r = 0.78, P < 0.0001) between the changes in PaCO(2) and the simultaneous changes in ETCO(2).ConclusionsIn ventilated VLBWI, the correlation between mainstream ETCO(2) and PaCO(2) is good, but the agreement is poor and negatively influenced by the severity of pulmonary disease. Capnography is feasible in ELBWI. ETCO(2) should not replace PaCO(2) measurements in ventilated VLBWI, but may have a role to detect trends of PaCO(2).Copyright © 2011 Wiley Periodicals, Inc.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.